3.1 Flexible Mining machine cable for rated voltage upto and including 1.9/3.3kV.
Executive standard: MT818.2 - 1999
Operating condition:
1). Rated voltage Uo/U is 0.38/0.66kV,O.66/1.14kV and 1.9/3.3kV.
2). Long-term operating temperature allowance of conductor for rated voltage upto and including 0.66/1.14kV is 65℃; Long-term operating temperature of conductor for rated voltage 1.9/3.3kV is 90 ℃.
3). The min.bending radius should be 6 times of cable outer diameter. Type,Designation and application of cable
| Type | Designation | Application |
| MC-0.38/0.66 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCP-0.38/0.66 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCP-0.66/1.14 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.66/1.14kV. |
| MCP-1.9/3.3 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 1.39/3.3kV. |
3.2 Rubber jacket shielded controlled flexible minning machine cable rated voltage 0.66/1.14kV
Executive standard:MT818.3-1999
Operating condition
1). Rated voltage Uo/U is 0.66/1.14kV.
2). Long-term operating temperature allowance of conductor is 90℃.
3). The min.bending radius should be 15 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MCPJB - 0.66/1.14 | Rubber jacket shield controlled wrapped strength flexible minning machine cable | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCPJR - 0.66/1.14 | Rubber jacket shield controlled wrapped strength flexible minning machine cable | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
3.3 Rubber jacket movable flexible cable for Rated Voltage upto including 0.66/1.14kV
Executive standard:MT818.5—1999
Operating condition
1 Fated voltage Uo/U is 0.38/0.66kV and 0.66/1.14kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MY-0.38/0.66 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 038/0.66KV |
| MYP-0.38/0.66 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 038/0.66KV |
| MYP-0.66/1.44 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 0.66/1.14KV |
3.4 Rubber jacket shielded flexible cable for Rated Voltage upto including 3.6/6kV
Executive standard:MT818.7—1999
Operating condition
1 Fated voltage Uo/U is 1.93/3kV and 3.6/6kV.
2.Long-term operating temperatrue allowance of conductor is 90℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MYPT-1.9/3.3 | Movable rubber jacket metalled shield flexible cable for coal mining | Connected power for winning machine under well rated voltage 1.9/3.3KV |
| MYP-3.6/6 | Movable rubber jacket shield flexible cable for coal mining | Connected power for minning machine on the groung rated voltage 3.6/6KV allowed ambient low-temperature is -20℃ |
| MYPT-3.6/6 | Movable rubber jacket metalled shield flexible cable for coal mining |
| MYDP-3.6/6 | Movable rubber jacket shield flexible cable for coal mining | Connected power for minning machine on the groung rated voltage 3.6/6KV allowed ambient low-temperature is -40℃ |
| MYDPT-3.6/6 | Movable rubber jacket metalled shield flexible cable for coal mining |
3.5 Drill cable for coal mining Rated Voltage 0.3/0.5kV
Executive standard:MT818.8—1999
Operating condition
1 Fated voltage Uo/U is 0.3/0.5kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MZ-0.3/0.5 | Rubber jacket drill cable for coal mining | Connected power for drill machine under well rated voltage upto and including 0.3/0.5kV |
| MZP-0.3/0.5 | Rubber jacket shield drill cable for coal mining |
3.6 Light type movable flexible cable for coal mining
Executive standard:MT818.9—1999
Operating condition
1 Fated voltage Uo/U is0.3/0.5kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MYQ-0.3/0.5 | Light type movable rubber jacketed soft cable for coal mining | Connected power lighting routing machine and signal equipment under well |
3.1 Flexible Mining machine cable for rated voltage upto and including 1.9/3.3kV.
Executive standard: MT818.2 - 1999
Operating condition:
1). Rated voltage Uo/U is 0.38/0.66kV,O.66/1.14kV and 1.9/3.3kV.
2). Long-term operating temperature allowance of conductor for rated voltage upto and including 0.66/1.14kV is 65℃; Long-term operating temperature of conductor for rated voltage 1.9/3.3kV is 90 ℃.
3). The min.bending radius should be 6 times of cable outer diameter. Type,Designation and application of cable
| Type | Designation | Application |
| MC-0.38/0.66 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCP-0.38/0.66 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCP-0.66/1.14 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 0.66/1.14kV. |
| MCP-1.9/3.3 | Rubber jacket flexible shield cable for minning machine | Connected power for minning machine and similar equipment rated voltage 1.39/3.3kV. |
3.2 Rubber jacket shielded controlled flexible minning machine cable rated voltage 0.66/1.14kV
Executive standard:MT818.3-1999
Operating condition
1). Rated voltage Uo/U is 0.66/1.14kV.
2). Long-term operating temperature allowance of conductor is 90℃.
3). The min.bending radius should be 15 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MCPJB - 0.66/1.14 | Rubber jacket shield controlled wrapped strength flexible minning machine cable | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
| MCPJR - 0.66/1.14 | Rubber jacket shield controlled wrapped strength flexible minning machine cable | Connected power for minning machine and similar equipment rated voltage 0.38/0.66kV. |
3.3 Rubber jacket movable flexible cable for Rated Voltage upto including 0.66/1.14kV
Executive standard:MT818.5—1999
Operating condition
1 Fated voltage Uo/U is 0.38/0.66kV and 0.66/1.14kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MY-0.38/0.66 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 038/0.66KV |
| MYP-0.38/0.66 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 038/0.66KV |
| MYP-0.66/1.44 | Rubber jacket flexible coal mining cable for movable type | Connected power for all kinds of movable for rated voltage 0.66/1.14KV |
3.4 Rubber jacket shielded flexible cable for Rated Voltage upto including 3.6/6kV
Executive standard:MT818.7—1999
Operating condition
1 Fated voltage Uo/U is 1.93/3kV and 3.6/6kV.
2.Long-term operating temperatrue allowance of conductor is 90℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MYPT-1.9/3.3 | Movable rubber jacket metalled shield flexible cable for coal mining | Connected power for winning machine under well rated voltage 1.9/3.3KV |
| MYP-3.6/6 | Movable rubber jacket shield flexible cable for coal mining | Connected power for minning machine on the groung rated voltage 3.6/6KV allowed ambient low-temperature is -20℃ |
| MYPT-3.6/6 | Movable rubber jacket metalled shield flexible cable for coal mining |
| MYDP-3.6/6 | Movable rubber jacket shield flexible cable for coal mining | Connected power for minning machine on the groung rated voltage 3.6/6KV allowed ambient low-temperature is -40℃ |
| MYDPT-3.6/6 | Movable rubber jacket metalled shield flexible cable for coal mining |
3.5 Drill cable for coal mining Rated Voltage 0.3/0.5kV
Executive standard:MT818.8—1999
Operating condition
1 Fated voltage Uo/U is 0.3/0.5kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MZ-0.3/0.5 | Rubber jacket drill cable for coal mining | Connected power for drill machine under well rated voltage upto and including 0.3/0.5kV |
| MZP-0.3/0.5 | Rubber jacket shield drill cable for coal mining |
3.6 Light type movable flexible cable for coal mining
Executive standard:MT818.9—1999
Operating condition
1 Fated voltage Uo/U is0.3/0.5kV.
2.Long-term operating temperatrue allowance of conductor is 65℃
3. The min.bending radius Should be 6 times of cable outer diameter.
Type,Designation and application of cable
| Type | Designation | Application |
| MYQ-0.3/0.5 | Light type movable rubber jacketed soft cable for coal mining | Connected power lighting routing machine and signal equipment under well |