Programmable salt spray test chamber
Programmable salt spray test chamber
Salt spray chamber is designed to carry out corrosion tests in a salt fog environment during its continuous or periodic spraying.
Technical specifications:
| Model | HD-60 | HD-90 | HD-120 | HD-160 | HD-200 |
| Internal dimensions (D*W*H) | 450*600*400 mm | 600*900*500 mm | 800*1200*500 mm | 1000*1600*500 mm | 1200*2000* 600 mm |
| External dimensions (D*W*H) | 672*1150* 1090 mm | 842*1450* 1200 mm | 1240*2080* 1285 mm | 1450*2480* 1520 mm | 1650*2900* 1550 mm |
| Lab Temperature | Saline testing method (NSS ACSS) 35℃±1℃/ Erosion-resistant testing method (CASS) 50℃±1℃ |
| Pressure pot temperature | Saline testing method (NSS ACSS) 47℃±1℃/ Erosion-resistant testing method(CASS )63℃±1℃ |
| Saline Temperature | 35℃±1℃ 50℃±1℃ |
| Lab capacity | 108 L | 270 L | 480 L | 800 L | 1440 L |
| Saline box capacity | 15 L | 25 L | 40 L | 40 L | 40 L |
| Saline concentration | Sodium chloride solution with 5% concentration or less than 0.26g copper chloride is added to each liter of sodium chloride solution with 5% concentration |
| Compressed air pressure | 1.00±0.01kgf/cm2 |
| Spray volume | 1.0~2.0ml/80cm2/h (at least collecting 16 hours and take the average value) |
| Relative humidity in the lab | Above 85% |
| Value PH | 6.5~7.2, 3.0~3.2 |
| Spray method | Programmable spray (including Continual spray and discontinuous spray) |
| Power | AC220V1Φ10A | AC220V1Φ15A | AC220V1Φ20A | AC220V1Φ20A | AC220V1Φ30A |