Dry dial with magnetic transmission, Vertical installation, Available for cold water (30°C) and hot water (90°C), sizes Ø 50 to 200 mm (2" – 8"). sealed mechanism with direct reading on numbered rolls. Brass ring. Horizontal Woltmann with removable insert. Used in industry. Pre-equipped for impulse emitter device (applicable even after installation). Equipped by stainless filter inside, First quality materials resistant to corrosion.
The series of water meter is used to measure the total quantity of cold potable water, consumed in household or a resident unit, passing through the large flow rater pipeline.
Feature:
•Easy maintenance due to removable measuring insert.
•Dry dial due to magnetic drive and counter clean and clarity.
•Full flow measuring.
•Suitable for fluctuating flow rates due towide measuring range.
•Low start-up flow and high sensitivity.
•Regulation in measuring insert(not in body).
•Integrated stainless steel filte.
•Long life bearings due to special wear-resistance materials.
•Large registing range due to 7-roller register.
•Metrological properties better than class B in GB/T778-1996 and in ISO 4064.
•All properties better than LXS water meter.
•Maximum corrosion protection by epoxy powder coating and stainless steel connecting.
•Remote-reading counter with multi pulse output available and relevant plug suitable to pulsing device of Reed,OPTO, Namur.
•Steel cap of counter is available according to requirement.
MAIN TECHNICAL DATA
| Size | Class | Flow rate | Reading |
| Min | Max |
| m3 |
| mm | Qp | Qmax | Qt | Qmin | |
| 50 | B | 20 | 30 | 1 | 0.2 | 0.05 | 0.01 | 999999.99 |
| 80 | B | 55 | 80 | 3 | 0.3 | 0.07 |
| 100 | B | 90 | 120 | 5 | 0.4 | 0.1 |
| 150 | B | 200 | 300 | 10 | 1 | 0.4 | 0.4 | 999999.9 |
DIMENSIONS AND WEIGHT
DN (mm) | L (mm) | H (mm) | Connccting Flange | W (Kg) |
Barer dia D | Boit cirele D1 | Conncctingboit numberholedia D1 |
| 50 | 280 | 220 | 165 | 125 | 4 - Φ 18 | 15 |
| 80 | 370 | 285 | 200 | 160 | 4 - Φ 18 | 27 |
| 100 | 370 | 300 | 220 | 180 | 8 - Φ 18 | 29 |
| 150 | 500 | 480 | 285 | 240 | 8 - Φ 18 | 80 |
Working condition:
Water temperature:≤50°C for cold water meter
Water temperature:≤90°C for hot water meter
Working pressure:≤1Mpa