Feature:Transmisson sensor: Reed switchMulti jet Dry dialMaterial body: Cast ironSzes Ø15 to 50mm, (½" – 2"), Available for cold water (30°C), hot(90°C)ISO 4064, Class B StandardUniversal use. Easy for interchange & maintenance
Specification:
Pulse constant: 1 liters/pulse, 10 liters/pulse or 100 liters/pulse for option
Type: Multi jet dry type water meter
MAIN TECHNICAL DATA
Meter size Dia DN (mm) | Class | qs Overload Flow | qs Nominal Flow
| qs Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
| m3/h | 1/h | m3 |
| 15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 |
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 |
| 25 | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
| B | 280 | 70 |
| 32 | A | 12 | 6.0 | 600 | 240 | 0.0001 | 99999 |
| B | 480 | 120 |
| 40 | A | 20 | 10 | 1000 | 400 | 0.001 | 99999 |
| B | 800 | 200 |
| 50 | A | 30 | 15 | 4500 | 1200 | 0.001 | 99999 |
| B | 3000 | 450 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
SELECTED METER TYPE
1. Reed switch
2. Connecting wire 1.5m
3. Sensor connecting means:
Three cores wire for reed switch
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.6Mpa