China Wholesale Low price Multi-jet lora module for Cold water meter smart water meter DN15-25 For OEM
Product Details
Our Advantages
Technical Parameters

Main techinical:

DN(mm)
Pure Water
15
20
25
(Q4)m³/h
1.25
3.125
5.00
7.875
(Q3)m³/h
1.00
2.50
4.00
6.30
(Q2)m³/h
0.01
0.05
0.08
0.126
(Q1)m³/h
0.00001
0.0313
0.05
0.0788
(Q3/Q1)
160/80
80
Error
Min Flow:≤±5% Q3;≤±2%(cold);≤±3%(hot)
Reading Range
0.00001-99999.99999
0.00001-99999.99999
Working Temperature
0.1°C-30°C
Cold Water Meter : 0.1°C-30°C
Hot Water Meter : 0.1°C-90°C
Permissible Pressure
0.03Mpa-0.5Mpa
0.03Mpa-1Mpa
0.3Mpa-1Mpa
Beginning Flow
2L/h(Drip Tight Water Meter)/0.00001
Static Working Flow
≤5μA(With Clock Chip)
Pressure Loss Level
△p63(≤0.063Mpa)
Flow Profile Sensitivity Level
U10,D5
Weather Mechanical Environment Safety Class
Class B
Electromagnetism Class
E1

Working condition
working temperature :cold water meter (0.1-30)℃, hot water meter (0.1-90)℃
working pressure:<1.0Mpa, working power: 3.6V Lithium Battery


Maximum permit error
From transitional flow rate (Qt) to maximum flow rate Qmax : ±2%
From minimum flow rate (Qt) to transitional flow rate Qmax : ±5%

Installation and maintenance:
1.The diameter of water meter is selected according to pipeline and flow rate ,not suitable for hot water;
2.Installation position need to avoid exposure ,frozen,pollution ,flooding .
3.Horizontal water meter be installed horizontally. For easily disassemble and assemble ,please make words face upward , and make the direction of the arrow on the case in the same direction of flow;
4.New pipeline must clean up the stone, sand and other debris
before install the water meter ,to avoid the water meter breakdown .
5.For collect measurement ,the faucet must higher than water meter ;the straight pipe connected to inlet of water meter must not less than 10D,the straight pipe connected to outlet of water meter must not less than 5D,D short for meter size.
6.Water meter should not be directly connected to the pipe ,the connections between the meter and pipeline should adopted connecting pipe, gasket, coupling nut ;when assembly and disassembly,must not forcibly pull hard ,to avoid unnecessary wrenching of water meter case which affect the
normal operation of the water meter
7.Meter above is prohibited put any items. Pay attention to moisture-proof and damp-proof ,strictly prohibit water droplets penetrate into meter controller which would damage control system and affect the normal use of the water meter .
8. Battery: 6 years