Welcome Customer !

Membership

Hangzhou Jebool Technology Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 汽车测试设备

Xwboo>Products

Hangzhou Jebool Technology Co., Ltd.Free·1YRS

  • E-mail

    info@jebool.com

  • Phone

    +86-571-88665293

  • Address

    1/F Building2, No.503 Xingguo Road, Linping District, Hangzhou 311100, China.

Contact Now

aPLI/Flex-PLI Dynamic Calibration System DCS-PLI

Model
Nature of the Manufacturer
Other
Product Category
Calibration System
Place of Origin
City, Province
Overview
aPLI/Flex-PLI Dynamic Calibration System DCS-PLI
Product Details
  • Suitable to aPLI and Flex-PLI;
  • According to NCAP and ECE R127;
  • Support aPLI Knee and Femur Inverse Impact Calibration;
  • Support Flex-PLI Inverse Impact and Pendulum Test;
  • Hanger Release time≤10ms;
  • Max. Impact Speed 12m/s;
  • Speed Control Error≤±0.1m/s;
  • Speed Feedback Measurement Sensor (Error≤±0.05m/s);
  • Hanger Position Shift Very Easy and Adjustable;
  • Certification Report is Generated Automatically.
The Dynamic Calibration System is designed for aPLI and Flex-PLI according to the requirements of NCAP and ECE R127. The system is modular in design, and the modules for the leg suspension can be quickly adjusted in height to accommodate shock calibration for aPLI and Flex-PLI. The suspension module has a height adjustment function to accommodate the dimensional tolerances. It adopts high-precision linear servo drive trolley, and the impact speed of the trolley is accurate and stable. The module for Flex-PLI pendulum calibration is driven by a servo motor and automatically lifts to a specified angle. It is automatically controlled by software, and the calibration report is automatically generated with customizedreport template as required.

Specification (Temperature 20℃±2℃, Humidify 30%~75%):
NameRequiredValue
Dimension (L×W×H) / mm3/3900*963*2400
Weight / kg/1500
Power Voltage / VAC/380
Power / kW/16
Impact Speed / m/s11.1≤12
Impact Speed Error / m/s≤±0.2≤±0.1
Moving Ram Weight / kg8.158.15
Ram Weight Error / kg≤±0.1≤±0.1
Ram Moving Friction / N≤100≤30
Free Distance Pre-impact / mm/≥70
Free Distance Post-impact / mm/≥190
Hanger Release Time / ms≤10≤10
Honeycomb (L×W) / mm2200*160200*160
Pendulum Additional Mass / kg55
Additional Mass Error / kg≤±0.05≤±0.05
Pendulum Suspension Angle / °1515
Suspension Angle Error / °≤±1≤±1

APLI Inverse Impact Calibration Picture:

Calibration Data Analysis Software:
  • ISO MME Data Import;
  • T0 Adjustable and CFC Filter Support;
  • Result Display and Report Generation.


aPLI/Flex-PLI Dynamic Calibration System DCS-PLI