RMR-40.5 Series Gas Insulated Ring Main Unit

Model
Nature of the Manufacturer
Other
Product Category
Metal Switchgear and RMU
Place of Origin
City, Province
Overview
RMR-40.5kV is completely insulated SF6 SAFERIN manufactured by Rockwill in China. This product is in conformity with the standards the GB/IEC standard and the design of a high safety combined switch cabinets.
Product Details

RMR-40.5kV is completely insulated SF6 SAFERIN (hereinafter short as SF6 insulated Ring Main Unit) This product is in conformity with the standards the GB/IEC standard and the design of a high safety combined switch cabinets.

The system of RMR-40.5kV of combined switch cabinets can be divided into three kinds of unit cabinet:

3 position cable connection unit (Cable switch unit), additional live shows and configuration of surge arresters and grounding fault component. Code C

3 position switch and fuse tripping system and earthing switch interlock system fuse combined electrical unit (Fuse combination unit), additional live shows and configuration of surge arresters and grounding fault component. Code F

3 position switch and vacuum circuit breaker combined appliances unit (Vacuum circuit breaker unit), additional current transformer, live shows and configuration of surge arresters and grounding fault component. Code V

The combination of the current transformer and the microcomputer protection to constitute the basic circuit protection function.

Microcomputer protection using passive protection and CT electric no need of additional PT power supply

 

Reference standard:

----IEC62271-200

----IEC62271-100

----GB3804-2004

----GB3906-1991

----GB16926-1997

----GB/T11022-1999

 

Remark:

Fuse combined electrical follow IEC 60420

VCB unit according to IEC 62271-100/GB1984-2003

 

NoItem UnitData
1Rate voltageKV36/40.5
2Power Frequency with stand voltageDry70/80/95
Wet
Lightning Impulse withstand Voltage (peak value)170/185/200
3Rate currentA630/1250(C)
4Rated short circuit breaking current(peak)KA20/25(V)31.5F
5Rated closed-loop breaking currentA630/1250(C)
6Rated cable charging interrupting currentA50©
7Rated line cable charging interrupting currentA10©
 Rated off circuit transformer breaking currentA16
8Rated naking current(peak)KA50(63/80)/2.5(main switch/grounding)
9Rated withstand current(peak)
10Rated short time withstand current16/20/25/31.5
11Rated short time withstand timeS3-4
12Mechanical lifetimesC/F(2000)V(10000)

a) Air temperature: ±40℃; Daily average ≤25°C

b)Altitude above sea level: Maximum installation altitude: 4000m

c)Wind: less than 35m/s;

d)Earthquake intensity: no more than 8 degrees;

Customized Panel ViewType & functionsW×D×H mm

Mainly for switching kiosk or

cable branch box

1C=500×950×1360mm

2C=1000×950×1360mm

3C=1500×950×1360mm

Extra bushing=140mm

 

Standard Panel View Unit CStandard Panel View Unit FStandard Panel View Unit V
500×950×1950500(568)×950×1950500(568)×950×1950

Note:

1, Unit V type LBS can be changed to be mounted on top for feeder cable outgoing system.

2, Unit V type incomer type with 3 nos VTs configuration width is 568mm.

3, Each unit can be connected with top busbar to be combined as Ring main unit

 

Standard economic type Ring main unit

Combination complete common gas tank CCF
Dimension 1500×950×1950
Vacuum circuit breaker unit for incomer using
Fuse combination for transformer protection using
Cable switch unit

Similar Product Recommend