Indoor SF6 Load Break Switch

Model
Nature of the Manufacturer
Other
Product Category
Switchgear Components
Place of Origin
City, Province
Overview
whole solution for load break switch(switch disconnector) 12kV,24kV,36kV. Rockwill Electric manufactures high quality indoor SF6 load break switch which is used in gas insulated switchgear and ring main unit (RMU). Contact for a low price.
Product Details

whole solution for load break switch(switch disconnector) 12kV,24kV,36kV

Load break switch compartment

Load break switch plus fuse combination compartment.

Upper Load break switch compartment

Lower Load break switch compartment.

RLS-12/24/36 an indoor high-voltage SF6 load switch, an switchgear with the rated voltage of 12kV/24kV/36kV, adopted with SF6 gas as an arc-extinguishing and insulation medium, including the three contactors for switching-on and switching-off and to-ground, and is characteristic in its small volume, its convenient installation and operation and its the great adaptability with surroundings.

RLS-12/24/36 of an indoor high-voltage SF6 load switch and RLS-12/24/36D of SF6 load switch plus fuse combination can function to protect and control the electric equipments for power supply and transformer substations especially being suitable for ring net cabinet, cable branch cabinet and distribution switching substation.

RLS-12/24 /36of an indoor high-voltage SF6 load switch and RLS-12/24/36D load switch plus fuse combination are complied with the standards of GB3804-1990, IEC60256-1,1997, GB16926, IEC60420 etc..

 

Matching dimension of SF6 load break switch-fuse combination

Fig 1) SF6 load break switch without upper cubicle

Dimension of indoor sf6 gas load break switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Primary loop of RLS type indoor load break switch and its combination is sealed in a epikote casted insulate unit by APG technology, this insulate unit has features of good insulating property, dust and dirts proof, insulate unit contains upper and lower insulate covers, inside charged 0.4bars pressure SF6 gas, the partial siding of lower cover is very thin, it's a protective measure and will burst out in the malfunction, the over pressed gas is released to protect the equipment.

SF6 load break switch and its fuse combination has open, close and earth three working position.

 

Operation principle of indoor sf6 gas load break switch

a) Earthing Position    b) Open Position    c) Closed Posit

 

RLS-36D load break switch adopts SF6 gas as the medium of arc extinction, when switch on and off, arc occurs and will spin under the magnetic field effect ion by the permanent magnet, cooled by the SF6 gas and extricated finally. This indoor SF6 load break switch and its fuse combination works with spring type operating

mechanisms A and K,RLS-24 load break switch equipped with the K spring operating mechanism is applied as the incoming control unit, while that equipped with A mechanism is applied as the outgoing protective unit and transformer unit.

1) "K" Type Spring Operating Mechanism

Working principle of K type spring operating mechanism is spring press and release( see fig 1. it's in off position)

A) Earthing operation

Driven by the handle, upper crank arm 4 rotates and presses spring 2 to store energy, when the max energy reached continue rotate the crank arm, the energy storage spring starts to release energy and drive the upper trigger, enables the connecting bar to drive the crank arm, crank arm rotates and drives the moving contactor for earthing.

B) Switch on operation

Driven by the handle, lower crank arm 1 rotates, presses spring 2 to store energy, when the energy released, it drives the trigger 8, enables connecting bar to drive the crank arm, crank arm rotates and drives the moving contactor and load break switch turns on.

C) Switch off operation

Rotate the main shaft crank arm counterclockwise by the handle, release the energy storage spring and the load break switch turns off.

2) "A" Type Spring Mechanism

Working principle of A type mechanism is same as K type, in addition, it has fuse striker trip function. For A type mechanism, electromagnetic trip is also available on customers requirement.(see fig 2)

A) Switch on operation

Driven by the handle, lower crank arm 1 rotates to presse switch on spring 12 and switch off spring 8 at the same time, to provide sufficient energy required by switching off. when the lower crank arm 1 buckles the pin and drives trigger to move, it makes the lower roller wheel tripd, and release the switch on spring and load break switch turns on.

B) Switch off operation

Press the switch off button or push the trip pin 2 by the fuse striker, release the spring and load switch turns off.

C) Earthing operation

Earthing operation of A type mechanism is same as that of K type.

3) K type and A type operating mechanism can be operated manually or motorized on request.

Notice: only when the load break turns off, can turning on and earthing operation be

mechanism of indoor sf6 gas load break switch

1-lower crank arm

2-energy storage spring

3-guider bar

4-upper crank arm

5-upper trigger

6-pull spring

7-main shaft crank arm

8-lower trigger

double spring mechanism indoor sf6 gas load break switch

1-lower crankshaft

2-trip pin

3-cam

4-lower roller wheel

5-upper roller wheel

6-upper crankshaft

7-upper guider bar

8-switch off spring

9-energy storage crank arm

10-main shaft crank arm

11-lower guider bar

12-switch on spring

Main technical data

No
Item
Unit
Parameter
1
Rated voltage
kV
12
24
2
Rated frequency
Hz
50/60
3
Rated current
A
630/800
4
 
1min Power frequency
withstand voltage
 
wet
kV
38
50
dry
kV
48
60
5
Lightning impulse withstand voltage
kV
75
125/150
6
Rated short circuit breaking current (peak)
kA
N/A
N/A
7
Rated active load and close circuit breaking current
A
630
630
8
Rated transferring current
A
1700
1200
9
Rated short circuit making current (peak)
kA
50
40
10
Rated cable(line) charging breaking current
A
50 and 10
11
Cable charge breaking current in earthing fault
A
20
20
12
Rated withstand current (peak)
kA
50
40
13
Short time withstand current (2s)
kA
31.5
25
14
Mechanism life
times
5000
5000

Main technical data

No
Item
Unit
Parameter
1
Rated voltage
kV
12
24
2
Rated frequency
Hz
50/60
3
Rated current
A
630/800
4
 
1min Power frequency
withstand voltage
 
wet
kV
38
50
dry
kV
48
60
5
Lightning impulse withstand voltage
kV
75
125/150
6
Rated short circuit breaking current (peak)
kA
N/A
N/A
7
Rated active load and close circuit breaking current
A
630
630
8
Rated transferring current
A
1700
1200
9
Rated short circuit making current (peak)
kA
50
40
10
Rated cable(line) charging breaking current
A
50 and 10
11
Cable charge breaking current in earthing fault
A
20
20
12
Rated withstand current (peak)
kA
50
40
13
Short time withstand current (2s)
kA
31.5
25
14
Mechanism life
times
5000
5000

Main technical data

No
Item
Unit
Parameter
1
Rated voltage
kV
36
40.5
2
Rated frequency
Hz
50/60
3
Rated current
A
630/800*
4
1min Power frequency withstand voltage
kV
70
80
5
Lightning impulse withstand voltage
kV
170
185
6
Rated short circuit breaking current (peak)
kA
N/A
N/A
7
Rated active load and close circuit breaking current
A
630
630
8
Rated transferring current
A
800
800
9
Rated short circuit making current (peak)
kA
40
40
10
Rated cable(line) charging breaking current
A
50 and 10
11
Cable charge breaking current in earthing fault
A
20
20
12
Rated withstand current (peak)
kA
40
40
13
Short time withstand current (2s)
kA
20
20
14
Mechanism life
times
2000
2000

Mechanism interlock

RLS-24D indoor type medium voltage SF6 load break switch and its fuse combination has

below interlocks:

A) When load break switch turns on, earthing operation can't be done

B) When earthing switch turns on, load break switch turns on/off operation can't be done

C) Interlock outlet of mishandling pretension is equipped

interlock of indoor sf6 gas load break switch

Installation, Adjustment

RLS-24D type load break switch has been strictly tested before outgoing from the factory, and fully meet the technical standards, must carefully read the installation manual and prepare as below before the installation and adjustment. Check the external appearance, any damage product is not allowed to use. Clean the equipment and get rid of the dust and dirt may caused by the transportation or other causes.

After installation, be sure the load break switch is turned off, insert the handle to the earthing operating hole in the up part of operating panel, rotate the handle clockwise in 180° to earth the switch, rotate counterclockwise in 180° to switch off the earth.

For switching on, turns off the load break switch firstly, insert the handle to the load break switch operating hole in the lower part of panel and turn on the load switch.

From the switch on to switch off, for K type mechanism, insert the handle to the load switch operating hole and rotate it in 180° to switch off; for A type mechanism, press the "switch off" button to switch off the load break switch, observe from the winder to confirm it, check whether the on/off indication plate works properly.

Notice: only when the load break turns off, can turning on and earthing operation be done !

 

Maintenance & Service

On condition of installing in environment as this manual required and normal operations, product guaranteed to be fault free for 10 years and has a running life of 25 years, but regular check per 6 months is required.

Keep the external appearance away from dust ,dirt and damp.

Lubricate and operate the mechanism for 3-5 times, check whether it acts properly.

Check with the pressure meter regularly, in case of meter data lower than 0.01MPa, should reload gas.

When the malfunction happens in the load break switch and fuse combination, and one of the three phase immediately, gas charging should be done by professional personnel from or trained by the manufacturer. uses burns out, all three fuses should be replaced at one time, must earth the switch before the replacement.

Matters need attention

It is NOT allowed to disassembly the self-sealed valve in front of switch( connecting end of meter).

It is NOT allowed to unload the seal screws on switch at any time. ++++Ordering Instructions

 

Ordering instructions:

1. Belowing terms should be marked while ordering:

Model number, product name and quantity.

Model of operating mechanism ( A,K ).

Provide the rated voltage specification if motorization operating is required.

For load break switch + fuse combination, fuse model and specification is required.

Other special requirements.

2. Documents with product from manufacturer:

Certificate of qualification.

Testing report for products.

Packing list.

Other technical documents.

indoor sf6 gas load break switch panel