33kV 11kV Oil Immersed Power Transformer

Model
Nature of the Manufacturer
Other
Product Category
Transformer Equipments
Place of Origin
City, Province
Overview
Low loss oil immersed distribution transformer is mainly made of iron core and windings which are placed in the oil tank that filled with insulating oil. It is mainly used for power plant, power transmission and distribution station as the equipment of power transmission.
Product Details

Low loss oil immersed type distribution transformer

1.Application

3.3kV-36kV transformers are mainly made of iron core and windings which are placed in the oil tank that filled with insulating oil.

It is mainly used for power plant, power transmission and distribution station as the equipment of power transmission.

2.Type and Rating

Product types: Single phase or three phases

Two windings or three windings

On-load or no-load voltage tap changer,

Autotransformer,

Natural cooling forced cooling or oil cooling, etc.

.Capacity range: 50kVA-5000kVA

.Frequency; 50/60Hz

3.Standard

IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc

 

11kV Series

Capacity (kVA)Voltage CombinationVector groupNo-load loss (W)Load loss (W) (75°C)Impedance voltage (%)  No-load current (%)
HVTapping range of HVLV
256 kV 6.6Kv 10.5kV 11kV  ±5%,±2×2.5%  0.38 kV 0.4 kV 0.415 kV 0.48 kV  Yyn0 Dyn5 Dyn111006004.01.7
501308701.6
6315010401.5
8018012501.4
10020015001.3
12524018001.2
16028022001.1
20034026001
25040030500.9
31548036500.9
40057043000.8
50068051000.8
63081062004.50.7
80098075000.6
10001160103000.55
12501360120000.5
16001640145000.45
20001940185005.50.4
25002300205000.4
Capacity (kVA)Voltage CombinationVector groupNo-load loss (W)Load loss (W) (75°C)Impedance voltage (%)  No-load current (%)
HVTapping range of HVLV
63013.2kV 13.8kV 15 kV 20 kV 22 kV 33 kV 34.5 kV  ±5%,±2×2.5%  0.38 kV 0.4 kV 0.415 kV 0.48 kV    Yd11115062004.50.9
800140075005.50.8
10001650103000.7
12501950128000.6
16002300145000.6
20002650171000.6
25003100200000.6
31503650237000.5
40004450281000.5
50005200327000.5
63006150369000.5
80008900440000.4
1000011600506006.50.4
Capacity (kVA)
Voltage
Vector group
No-load loss (W)
Load loss (W)
(75°C)
Impedance voltage (%)
No-load current (%)
Primary
Tapping range (%)
Secondary
50
33 kV
±5%
 
0.38 kV
0.4 kV
0.415 kV
0.48 kV
 
 
Yyn0
6.5
1210
6.5
2.0
100
305
2020
1.80
125
340
2380
1.75
160
360
2830
1.65
200
430
3300
1.55
250
510
3950
1.40
315
610
4750
1.40
400
735
5750
1.30
500
870
6900
1.30
630
1040
8250
1.25
800
1250
9900
1.05
1000
1480
12150
1.00
1250
1760
14600
0.90
1600
2130
17500
0.85
2000
2500
20680
0.75
2500
2975
24500
0.75
 
Capacity (kVA)VoltageVector groupNo-load loss (W)Load loss (W) (75°C)Impedance voltage (%)No-load current (%)
PrimaryTapping range (%)Secondary
5033 kV±5%  0.38 kV 0.4 kV 0.415 kV 0.48 kV    Yyn06.512106.52.0
10030520201.80
12534023801.75
16036028301.65
20043033001.55
25051039501.40
31561047501.40
40073557501.30
50087069001.30
630104082501.25
800125099001.05
10001480121501.00
12501760146000.90
16002130175000.85
20002500206800.75
25002975245000.75