Welcome Customer !

Membership

Zhejiang Volcano electrical technology Co., Ltd
Free Member ·1YRS
Other

Main Products: 断路器

Xwboo>Products

Zhejiang Volcano electrical technology Co., LtdFree·1YRS

  • E-mail

    info@volcano-electrical.com

  • Phone

    +86-577-61668058

  • Address

    Building 2,59, Weishiliu Road, Economic Development Zone, Chengdong Street, Yueqing, Zhejiang, China

Contact Now

Sf6 Medium Voltage Switch

Model
Nature of the Manufacturer
Other
Product Category
Indoor Load Break Switch
Place of Origin
City, Province
Overview
FLRN36-12, with rated voltage of 12kV , is a kind of SF6 gas insulated load break switch(LBS) combination with fuse
Product Details

Description:

FLN36-12D, FLRN36-12D sulfur hexafluoride load switch, load switch-fuse combination, and loadable cable head load switch are designed and developed by our company by absorbing foreign advanced technology and combining with the operating requirements of our country.

The product has three positions of arc extinguishing chamber, which is reliable in interlocking , high insulation strength at breakage, large climbing distance design, and the outlet end is protected by voltage sharing protective cover.

The switch has a special dynamic seal and fixed seal design, reliable seal, and is equipped with pressure gauge in obvious position. It is a new generation of high voltage switchgear equipped with urban power grid for operation monitoring to ensure operation safety.

This product is suitable for three-phase AC 10KV, 50HZ power systems, industrial and mining enterprises, high-rise buildings, residential areas, pre-installed substation places, used to open and close the load current, fault current, control and protection lines and distribution transformers.

sf6-disconnector-switch

Use environmental conditions

Ambient temperature: -15ºC~+40ºC;

Altitude: no more than 1000m;

Relative humidity: the average value of daily relative humidity shall not exceed 95%, the average value of monthly relative

humidity shall not exceed 90%, the average value of daily water vapor pressure shall not exceed 2.2kPa, and the average value of monthly water vapor pressure shall not exceed More than 1.8 kPa;

The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV.

sf6-gas-insulated-load-break-switch

The name of theunitsdata
FLN36-12DFLRN36-12D
The rated voltage
12 12 
Rated frequency
50 / 6050 / 60
Rated currentA630 1250 
Load switch rated short - term tolerance current/rated short - circuit durationkA/S20/3-
Ground switch rated short-time tolerance current/rated short-circuit durationkA/S20/2-
Rated peak tolerance current and rated short-circuit closing currentkA50125 expect )
rated breaking current Active load breaking currentA630 -
Closed-loop breaking currentA630 -
5% rated active load breaking currentA31.5 -
Turn off the cable charging currentA10-
Turn off the no-load transformer capacityKVA12501250
Turn off the transfer currentA-1700
Expected short circuit breaking currentkA-50
Rated insulation level1minl frequency withstand voltage phase, to ground/offKV42/4842/48
Lightning shock withstand voltage phase, to ground/offKV75/8575/85
Mechanical life
500500
SF6 rated air pressure (gauge pressure at 20°C)"MPa0.04-0.050.04-0.05

The technical parameters of the form are for reference only. 
Customized products can consult online customer service!