Miniaturization Vacuum Interrupter

Model
Nature of the Manufacturer
Other
Product Category
Vacuum Interrupter
Place of Origin
City, Province
Overview
TD series vacuum interrupter, is essential part for medium and high voltage breakers.
Product Details

Product description

Volcano main products include vacuum interrupter, embedded pole etc. electrical products. Vacuum interrupter is ceramics type, and the range of voltage is from 1.14kV to 40.5kV, current from 63A to 4000A, rated short circuit breaking current from 2kA to 40kA. Volcanoproducts are complied with relevant national standards and international standards (GB standards and IEC standards). After three large scale technical transformation, introducing advanced production processing equipment from Germany and United States, Volcano has the first-class technology equipment and perfect testing means, and products with the characteristic of standardization, seriation, miniaturization, specialization. For the meantime, Volcano has an experienced R&D team, and a complete , mature R&D program, a special department to organize the development of new products. In order to accurately grasp the development trend of industry technology , Volcano establishes a long-term good relation of cooperation with other well-known domestic and foreign institutions, and carry out technical exchanges with the international well-known enterprises to jointly develop the key products leading the market trend.



  • QQ图片20191210150219



Main technical parameter

Parameter itemUnitData
Rated voltagekV3.6
Rated currentA200
Rated frequencyHz50/60
Rated short-time power frequency withstand voltage(1 min)kV18
Rated lightning impulse withstand voltagekV28
Rated connecting currentA2000
Rated breaking currentA1600
Rated maximum sectional currentA2000
Rated minimum sectional currentA40
Rated short-time withstand currentA2000
Rated short-circuit durations4
Mechanical life ten-thousand times100
Rated breaking time AC3ten-thousand times15
Rated breaking time AC4ten-thousand times6
Contact closing force due to bellows and atomsphereN50±10
Force required to hold contact open at full strokeN65±15
Circuit resistance at rated contact forceμΩ≤100
Contact limit erosionmm2
Storage lifeyear20


Specifications required for matched switchgear

Parameter itemUnitData
Rated clearance between open contactsmm3±0.3
Average opening speedm/s0.6±0.1
Average closing speedm/s0.3±0.1
Rated contact pressureN100±20
Contact bouncing duration at closing operationms≤3
Closing and opening non-simultaneity of contactsms≤2
Rated contact strokemm1.5±0.3


In mounting, attention should be paid to the following:


    a. When operating, guide unite unit must be provided for the interrupter. The coaxality of moving conducting pole and axial line of interrupter must meet the requirement. There should not be torque force applied on the bellow.


   b. When mounting, it is forbidden to beat or strike the interrupter envelop with hard things in case crack may occur to cause air leakage.


     c. Take care to assure that the conducting pole must be coaxial with interrupter, and that the conducting pole must be vertical on the face of fixed end


     d. Take care not to disassemble the interrupter repeatedly to prevent screw from slipping. There should not be twisting on the moving conducting pole and over press on bellow to avoid that any torque force and scratch may occur to bellow to reduce its service life.


     e. During mounting, the force applied on the face of both ends should not go beyond the static relief pressure stipulated in the specification.

Similar Product Recommend