Overview
The Fuse Cutout are connected with the incoming feeder of the distribution transformer or distribution lines. These are primary used to protect transformers or lines from short circuits and overloads and switching currents.
Product Details

Overview


The sectionalizer is applied in three phase power system with AC 50Hz and rated voltage 10-40.5kV. It is installed on distribution overhead line to isolate fault when corporate with recloser or circuit breaker. When fault occurs on the line, the faults current reaches or exceed preset threshold value, the sectionalizer can memorize the tripping times of upstream recloser. When it reaches preset times, it drops down to trip automatically.


Sectionaliser will drop down to trip automatically on the condition as given below:

First, the faults current exceeds presetting pickup current. Next, the counting time reaches presetting value (1, 2, 3 or 4). Third, the circuit loses voltage and the current is lower than 300mA. And then the Sectionlizer will trip automatically when the aforesaid conditions occur simultaneously. If any of aforesaid conditions doesn't occur, the Sectionlaizer will not trip automatically.


High-Voltage-Porcelain-Fuse-Switch-Disconnector-HSF-12kv-

Using Enviroment:

1. The ambient air temperature is not above 55ºC or below -40ºC. 
2. The average value of the ambient temperature, measured over a period of 24h, does not exceed 25ºC. 
3. The altitude does not exceed 1000 m (3300ft). 
4. The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindrical surfaces). 
5. The ice coating does not exceed 1mm. 
6. The sectionalizer should not apply to those flammable, explosive, corrosive and severe vibration conditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturer for detail information. 