Fixed Metal Enclosed Switchgear

Model
Nature of the Manufacturer
Other
Product Category
Switchgear
Place of Origin
City, Province
Overview
XGN15-12 air insulated switchgear(VCB type) is the latest generation of metal enclosed switchgear, which adopts vacuum switch for arc extinguishing, air as insulation, suitable for distribution automation, compact and expandable.
Product Details

PRODUCT DESCRIPTION


XGN15-12 air insulated switchgear(VCB type) is the latest generation of metal enclosed switchgear, which adopts vacuum switch for arc extinguishing, air as insulation, suitable for distribution automation, compact and expandable.

The switchgear has the characteristics of simple structure, flexible operation, reliable interlocking and convenient installation. It can provide satisfactory technical solutions for various application occasions and different user requirements. With the adoption of voltage and current sensing technology and new relay protection device, as well as advanced technical performance and light and flexible assembly scheme, the switch cabinet can be used in hospitals and airports with strict operation requirements, and can fully meet the changing needs of the market.

The main switch of XGN15-12(VCB type) switchdear adopts  VS1-12 series VCB, or ABB VD4-12 series VCB and Schneider EV12 series VCB. The vacuum circuit breaker can break short circuit high current and rated load current. Cooperating with related components can realize the protection of lines and various loads, realize the selective action between the upper and lower levels of power supply lines, and improve the control and protection function of power supply quality in the power system.


NORMAL USE CONDITIONS


  1. Altitude ≤ 1000M

  2. Ambient temperature: - 10 ℃ - 45 ℃, maximum temperature difference ≤ 25 ℃

  3. Relative humidity: the average daily relative humidity shall not exceed 95%

  4. The average monthly relative humidity shall not exceed 90%

  5. Seismic capacity: ground horizontal acceleration ≤ 0.4m/s2

  6. Ground vertical acceleration ≤ 0.2m/s2

  7. There is no violent vibration and impact and places with fire, chemical corrosion and explosion risks.