High Frequency Online UPS HP9335C Plus 10-30KVA 3Ph in / 3Ph out Online UPS,isolation transformer offer full isolation,support N+X parallel redundancy and Maintenance bypass,EPO/ECO/SNMP/USB/RS232 optional.
Key Features:
1.True double-conversion
2.DSP technology guarantees high performance
3.Output power factor 0.9
4.Wide input voltage range (110-300 VAC)
5.Active power factor correction in all phases
6.50Hz/60Hz frequency converter mode
7.ECO mode operation for energy saving
8.Accepts dual-mains inputs
9.Emergency power off function (EPO)
10.Generator compatible
11.SNMP+USB+RS-232 multiple communications
12.3-stage extendable charging design for optimized battery performance
13.Adjustable battery numbers
14.Maintenance bypass available
15.Optional N+X parallel redundancy
16.Optional isolation transformer offers full isolation and complete common mode noise rejection
| MODEL | HP9335C Plus 10-30KVA |
| 10K | 10K-XL | 15K | 15K-XL | 20K | 20K-XL | 30K | 30K-XL |
| CAPACITY | 10KVA / 9KW | 15KVA / 13.5KW | 20KVA / 18KW | 30KVA / 27KW |
| PHASE | 3 Phase with Neutral |
| INPUT |
| Voltage Range | Low Line Loss | 110 VAC(Ph-N) ± 3 % at 50% Load ; 176 VAC(Ph-N) ± 3 % at 99% Load |
| Low Line Comeback | Low Line Loss Voltage + 10V |
| High Line Loss | 300 VAC(Ph-N) ± 3 % |
| High Line Comeback | High Line Loss Voltage - 10V |
| Phase | Three phase with ground |
| Power Factor | ≥ 0.99 at 99% Load |
| OUTPUT |
| Output voltage | 208/220/230/240VAC(Ph-N) |
| AC Voltage Regulation | ± 1% |
| Frequency Range (Synchronized Range) | 46Hz ~ 54 Hz @ 50Hz system ; 56Hz ~ 64 Hz @ 60Hz system |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
| Overload | AC mode | 99%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec |
| Battery mode | 99%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec |
| Current Crest Ratio | 3:1 max |
| Harmonic Distortion | ≦ 2 % @ 99% Linear Load; ≦ 5 % @ 99% Non-linear Load |
| Transfer Time | Line←→Battery | 0 ms |
| Inverte←→Bypass | 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass) |
| Line←→ECO | <10 ms |
| EFFICIENCY |
| AC mode | > 89% | > 89% | > 89% | > 90% |
| Battery Mode | > 86% | > 88% | > 87% | > 89% |
| BATTERY |
| Standard Model | Type
| 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah |
| Numbers | 20(18-20 adjustable) | 2 x 20(18-20 adjustable) | 2 x 20(18-20 adjustable) | 3 x 20(18-20 adjustable) |
| Recharge Time | 9 hours recover to 90% capacity |
| Charging Current | 1.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 4.0 A ± 10% (max.) |
| Charging Voltage | 273 VDC ± 1% |
| Long-run Model | Type | Depending on applications |
| Numbers | 18-20 |
| Charging Current | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 12.0 A ± 10% (max.) |
| Charging Voltage | 273 VDC ± 1% |
| PHYSICAL |
| Standard Model | Dimension,DxWxH(mm) | 832 X250X894 | 832 X250X1275 |
| Long-run Model | Dimension,DxWxH(mm) | 609 X250X768 | 832 X250X828 |
| ENVIRONMENT |
| Operation Temperature | 0 ~ 40°C (the battery life will down when > 25°C) |
| Operation Humidity | <95 % and non-condensing |
| Operation Altitude | <1000m |
| Acoustic Noise Level | Less than 58dB @ 1 Meter | Less than 60dB @ 1 Meter |
| MANAGEMENT |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC |
| USB | Power management from SNMP manager and web browser |