Technical Parameter:
| Density of Alarm | City Gas 0.5~1.0% | Natural Gas 0.5~1.5% | LPG 0.5~1.0% |
| Voltage | AC220V 50Hz / DC12V (Please confirm the voltage while buying) |
| Standby Power | <0.5W |
| Max Power | ≤2.0W |
| Alarm | Alarm with beep, green LED off, red LED blinks. If there is a manipulator or solenoid value connected, it will turn off the gas automatically. |
| Response/Recovery Time | ≤30s |
| Working Mode | Momentary / Toggle / Latching |
| Environment | Humidity≤97RH Temperature -15~+50℃ |
Installation:
1.The gas alarm should be installed in 1.5m from the gas source, and 0.3m above the ground for LPG, 0.3m below the ceiling for natural gas, city gas and CO. The installation site should be airy.
2.Please don’t install the alarm in airless place, such as the corner, inside cupboard or where is full of lampblack.
3.Connection diagram:
There are 3 versions of the gas alarm, the connection ways are different:
(1)Independent version: Working independently, or connect GND and M+ to solenoid valve, refer to Figure 1 &2.
(2)Wired version: Output relay signal when alarm, you can connect it to ventilator. Refer to Figure 1.
(3)Wireless version: Transmits RF signals when alarm.

Operation:
1.Green LED: Power indicator, always ON while working, OFF while alarming.
2.Red LED: Alarm indicator, always OFF while working, blinks while alarming.
3.Test button: push once to enter test status, green LED OFF, red LED blinks, alarm beeps.
4.Working: Connect the device to power source, green and red LED both ON, then green LED OFF and red LED blinks after a beep. 3 minutes later, red LED OFF, green LED ON, the device works normally.
Notice:
The correct method while alarming is to open doors and windows immediately, turn off the gas source. DON NOT turn ON/OFF any power switch.
Warranty:
1.The period for protecting to fix is one year. (From the day when you buy) During this period, any belongs to under normal usage circumstance cause because of the product quality's problem of breakdown, we will be responsible for giving free maintain. However, it doesn’t include enclosure, label, package and so on.
2.The service life of gas alarm is 3 years, please replace it with new ones after 3 years.