12kV 24kv 36kv SF6 GAS INSULATED LOAD BREAK SWITCH WITH REMOTE OPERATION FACILITY
General
The LBS will be used in overhead distribution networks to isolate sections of the main distribution lines / branches (spurs) of the lines.
LBS shall be of three phase SF6 Gas Insulated type suitable for outdoor applications.
Design
I. The LBS shall be of compact, light weight, maintenance free type that can be easily mounted on single pole / double pole or gantry structures as mentioned in the price schedule. It shall be tropicalized in accordance with clause 3.0. Evidence of operational endurance in service, and design features to guarantee maintenance free performance shall be furnished with the offer.
II. LBS shall be complete with operating mechanism and all other components necessary for installation and operation. It shall have the facility
(a) to control LBS (ON/OFF) by rod assembly and it shall be able to lock the operating handle at ON/OFF/Electric Modes using a padlock or suitable device. The operating handle shall be horizontal at 2.5 feet above the ground level.
(b) to control LBS (ON/OFF) by means of activating a switch button by an operator which is placed at the LBS mounting poles / structure in an level accessible to operator.
(c) to monitor and control LBS remotely from CEB control station. LBS shall contain Remote / Local (means operating by rod assembly or switch button) control switch to select the required mode of operation. It shall incorporate a Remote Terminal Unit (RTU) compatible with GSM/GPRS communication module that allows the LBS to be controlled directly. The communication protocol shall conform to
IEC 60870-5-101& 104 or latest versions of them.
Following communication ports shall be provided for SCADA and local configuration.
RS232 (SCADA)
Ethernet RJ45
RS232 (Local configuration)
USB (Local configuration)
The RTU shall communicate and shall allow for the processing of all analogue and digital signals including inputs, outputs, measurements and alarms in order to monitor and control the LBS remotely. The power supply for RTU shall be provided from internal battery.
Voltage detection on both sides of the opened switch shall be possible from the control centre. The measurement of line parameters (line voltages: on both side of one phase, phase currents) and maintenance information (SF6 gas pressure indication, retrieval of ‘Number of switching operations performed’) shall be possible from the control centre. Periodical, continuous and on – request remote data acquisition modes shall be available.
The LBS monitoring and control software for local and remote operation which is compatible with windows 7 or later version shall be provided. The software should have the facility to install on any computer without a separate license CEB SPECIFICATION 023: 2013 5/12 and record the event history to get the information of the access user. The software should have separate authority levels for
(i). Programing, Control and Monitoring
(ii). Control and Monitoring
(iii). Monitoring
The offered software should be backward-compatible with the previous version.
(d) Compatibility issues related with the existing SCADA system and other technical compliances, if required shall be mentioned in the Annex B and shall be provided as mentioned in the price schedule. The supplier shall provide a list of non compliances.
(e) The RTU shall be firmware upgradable.
III. Operation of LBS shall be able
(a) Possible by operating with a rod assembly as per clause 5.2 II.(a)
(b) Possible by activating a switch/button as per clause 5.2 II.(b)
(c) Possible via remote as per clause 5.2 II.(c)
(d) even when the line is de-energized from both load and source sides and when no external supply is available. In such a situation, LBS shall be able to carry out at least 8 nos. operations (ON or OFF) by activating the control push button as per 5.2 II. (b) above or by remote operation as per 5.2 II. (c) above, within 48 hours period.
(e) If any voltage is detected on both sides of the opened switch, i. Closing operation or in other words switching ON the LBS shall be allowed, only after the reconfirmation from the authorized person from the control centre.
(f) If dead line is detected either in source side or in load side, the closing operation in electric/remote mode shall be possible.
IV. The battery, charging and other control circuitry shall be an integral part of the LBS. Battery shall be sealed maintenance free rechargeable type having a minimum service life time of 5 years or 2000 on/off operations.
V. Auxiliary power supply for battery charging for above IV shall be 230V, 50 Hz Single phase.
VI. Each LBS shall have its own self contained operating mechanism and self supporting control unit with software as applicable. All components that might be adversely affected by water and / or dust shall be housed in lockable cabinets having a degree of protection to IP54. Anti condensation heaters to eliminate the formation of condensation shall be included as required.
VII. Surge arrester mounting brackets on both sides of LBS shall be provided.
VIII. All three poles of the LBS shall be operated simultaneously by the operating mechanism.
IX. A mechanical position indicator shall be provided to indicate the ON/OFF position of the LBS. This indicator shall be a light reflecting mechanical ON/OFF position indicator, so that the position of the switch can be clearly seen from the ground even under bad weather conditions.
X. All non metal parts including insulating materials of cables shall be able to withstand effects due to ultra violet radiation.
XI. An earthing terminal shall be provided for bonding the LBS metal work and mounting frame to the local earthing electrodes / galvanized steel mounting structure. The mounting frame shall have an earthing terminal suitable to accommodate two Nos. 5mm dia. to 15mm dia. CEB SPECIFICATION 023: 2013 6/12 earthing conductors. The mounting frame shall be suitable for single pole mounting/double pole structure mounting and steel gantry structure mounting.
XII. The switch operating mechanism shall incorporate a reliable locking mechanism and a locking device to lock the switch button in ON/OFF position.
Bushing Insulator
1.Bushing/housing insulator shall be of the Polymeric type and terminals shall be of the universal clamp type to accommodate copper/aluminium conductors of diameter ranging from 12mm to 20 mm.
2. SF6 LBS Tank Tank used to enclose SF6 gas for insulating purposes shall be made of stainless steel and of robust construction based on the design requirements of pressurized enclosures. Tank shall have a degree of protection to IP54.
Tanks exposed to the decomposition products of SF6 gas shall be fitted with appropriate filters sufficient for the life of the equipment. Gas filling valve shall be provided for topping up of the SF6 gas. Provision to prevent explosion during internal arc fault shall be provided. Alternatively, hermetically sealed type tanks are acceptable.
Insulation and Interrupting Media
I. The insulation media of the LBS shall be SF6 and the interrupter shall be SF6 or Vacuum type. Gas seals shall be designed to prevent the leakage of gas or ingress of moisture throughout the service life.
II. Following safety requirements shall be incorporated to LBS:
(a) Features to ensure the safe release of internal over pressure exceeding the safe design pressure shall be provided.
(b) A SF6 gas pressure indicator shall be provided to indicate the gas pressure. The indication shall be visible from the ground. Devices to protect against maloperations due to insufficient gas pressure shall also be included.
(c) It shall be fitted with appropriate filters sufficient for the durability of the equipment to minimize the presence of moisture and SF6 decomposition products.
Technical Requirements
(a) Rated voltage kV 12 36
(b) Frequency Hz 50 50
(c) Continuous current rating A 400 400
(d) Rated Short Circuit Making Current peak kA 31.5 40
(e) Rated Short time current (1 second) RMS kA 12.5 16
(f) No. of operations at rated Full Load 300 300
(g) Mechanical endurance (operations) Class M2 general Purpose switch IEC 60265-1 5000 operations
(h) Fault making Operations Class E3 general purpose switch IEC 60265-1 Minimum of 5 making operations at the fault making current in Section 5.6 (d)
(i) No load transformer breaking current Equivalent to no load current of a 1250kVA Transformer
(j) Rated line charging breaking current 10A 10A
(k) Rated insulation levels
(a) Lightning Impulse withstand voltage (1.2/50 s) kV peak dry.
i. Between earth and terminals of switches (of same phase) kV 75 170
ii. Across the terminals of open switches kV 85 195
(b) 1 min. power frequency withstand voltage wet.
i. Between earth and terminals of switches (of same phase) kV 28 70
ii. Across the terminals of open switch. kV 32 80
(l) Operating mechanism
(a) Manual operation by rod assembly
(b) By activating a local switch by the operator
(c) Remote operation from CEB control center
(m) Gas pressure monitoring shall be provided
(n) Trip Counter shall be provided through software
Galvanizing
I. All iron and steel parts (except stainless steel parts) such as mounting and support brackets, bolts and nuts, washers shall be galvanized after the process such as sawing, shearing, drilling, punching, filling, bending and machining are completed.
II. Galvanizing shall be of the hot-dip process to comply with BSEN ISO 1461:1999 standards.
Type Test
The following certificates of type tests shall be carried out, in accordance with the IEC 60265-1
(a) Lighting impulse withstand voltage test
(b) Power frequency (wet) withstand voltage test
(c) Temperature rise test
(d) Making and breaking test for specified currents
(e) Short time withstand current test
(f) Peak withstand current test
(g) Measurements of resistance of the main circuit
(h) Test to prove satisfactory mechanical operation and endurance
(i) Verification of protection
(j) Tightness tests
(k) Electromagnetic compatibility (EMC) tests
Test Certificates, based on the type tests conforming to relevant standard shall be supplied along with the offer. The test certificates should clearly identify the equipment concerned, showing the manufacturer's identity, type number and basic technical parameters. The Test certificates referred to shall be from an accredited independent testing laboratory acceptable to the purchaser. Proof of accreditation by a national/ international authority shall be forwarded with the offer. Test reports shall be complete including all the pages as issued by the testing authority. Parts of test reports shall not be acceptable.
Quality Assurance
The manufacturer shall possess ISO 9001:2008 quality assurance certification for the manufacture of gas insulated SF6 circuit breakers for the plant where the manufacture of the LBS is done.
The bidder shall furnish a copy of the ISO certificate along with the offer. This document shall be certified as a true copy of the original by the bidder.