VS1 Specification:
VS1-12 Series Indoor AC HV Vacuum Circuit Breaker is an indoor HV switchgear of three-phase AC 50Hz and rated voltage 12kV. Circuit breaker can be proceed frequent operation and has many times breaking and rapid reclosure capacity, and has reliable interlock function. The device is front and back split charging structure, not only as a fixed installation unit but also match handcart unit with base plate cart.
The product complies with GB1984, IB3855, DL403 and IEC56.
VS1-12 type indoor high voltage vacuum circuit breaker, three-phase AC 50Hz, rated voltage for indoor switchgear 12KV power system, protection of power equipment enterprises. As a condition of power equipment and control unit. The frequent operation is suitable for requirements in the rated working current, or multiple breaking short circuit current.
The circuit breaker adopts the operating mechanism and the circuit breaker body integral design, can be used as a fixed installation unit, also can be equipped with a special propelling mechanism, which is composed of the action of the hand car unit.
Main Technical Parameters
Item | Description | Unit | Data | |
1 | Rated voltage | KV | 12 | |
2 | Max. voltage | KV | 12 | |
3 | Rated current | A | 1250/1600/2000/2500/3150 | |
4 | Rated break current on shorting | KA | 31.5/40/50 | |
5 | Rated short circuit making current | KA | 80/100/125 | |
6 | Rated peak withstand current | KA | 80/100/125 | |
7 | 4S Rated withstand current | KA | 31.5/40/50 | |
8 | Rated insulation level | Power frequency voltage(when losing a circuit) | KV | Dreaker 48 |
Impulse withstand voltage(when losing a circuit) | Dreaker 84 | |||
9 | Rated operating sequence | OC-0.3s-CO-180S-CO | ||
10 | Mechanical life | Times | 10000 | |
11 | Open circuit times of rated short dropout current | Times | 50 | |
12 | Rated close brake voltage of operating machnie | V | 110,220 | |
13 | Rated break brake voltage of operating machnie | V | 110,220 | |
14 | Clearance between open contacts | mm | 11±1 | |
15 | Exceed range(the compress length of contact sping) | mm | 4±0.5 | |
16 | Different period of three-phase break and close break | ms | ≤2 | |
17 | The jump time of contact close break | ms | ≤2 | |
18 | Average break speed | m/s | 0.9~1.2 | |
19 | Average closing speed | m/s | 0.6~1.2 | |
20 | Opening time | Ubder max.operating voltage | S | ≤0.05 |
Under min.operating voltage | ≤0.08 | |||
21 | Closing time | s | ≤0.1 | |
22 | Resistance of each phase main loop | μΩ | ≤40 | |
23 | Contacts limit ersion | mm | 3 | |
Note:
Please contact the factory to confirm the latest parameters
Outline and installation dimension