SF6 Load Break Switch Power Distribution Substation RMU

Model
Nature of the Manufacturer
Manufacturer
Product Category
SF6 Load Break Substation
Place of Origin
City, Province
Overview
XGN15-12(L)/T630-25 0r XGN15-12(L . R)/T100-31.5 box-type fixed AC metal enclosed switchgear is mainly used for looped network po biradial power supply of electric power system with 3-phase ,AC 50Hz and rated voltage 10KV. It also can be used for terminal power supply as the control device of electric energy and protection device of utilization equipment.
Product Details

image001


Brief Introduction:

XGN15-12(L)/T630-25 0r XGN15-12(L . R)/T100-31.5 box-type fixed AC metal enclosed switchgear is mainly used for looped network power supply or biradial power supply of electric power system with 3-phase ,AC 50Hz and rated voltage 10KV. It also can be used for terminal power supply as the control device of electric energy and protection device of utilization equipment. More over, it also can be suitable for this switchgear to be installed in the box substation, especially compact box substation.


Service Environmental Condition:

⑴ Altitude: .< l000m

⑵Ambient temperature: -25aC ~ +400C

⑶Relative humidity: The daily average value is not more than 95% and the monthly mean value is not more than 90%.

⑷The surrounding air shall not be polluted by corrosive gas and flammable gas as well as water vapor and so on obviously.

⑸. No location of recurrent strenuous vibration



The main technical parameters:

NO.

Item

Unit

Technical parameters

XGN15-12(F)

XGN15-12(F,R)

1

Rated voltage

KV

12

2

Rated Frequency

Hz

50

3

Rated insulation level

1 min power frequency withstand voltage

Kv

To-Grounding and phase -to-phase42;Isolating distance48

Lighting impulse withstand voltage(peak)

kv

To-Ground and phase-to-phase 75;
Isolating distance85

4

Rated current of main bus

A

630

6

Rated current

A

630

125

7

Rated closed loop breaking current

A

630


8

Rated charging breaking current

A

10

9

Rated transfer current

A


1700

10

Breaking no-load transformer capacity

KVA

1600

11

Rated making current(peak)

KA

63


12

Rated short-time withstand current

KA

25


13

Rated peak withstand current

KA

63


14

Rated short-circuit breaking current

KA



15

Peak withstand current of ground circuit(prospective)

KA

63

31.3(Prospective)

16

Short-time withstand current of grounding circuit

KA

25

17

Fuse model



S□LAJ

18

Rated voltage of auxiliary circuit

V

DC220 110 AC220 110

19

IP Code


IP3X


20


Mechanical life

Load switch (times)

Times

5000

Earthing switch(times)

Times

2000


Cabinet type: