Switch type - stainless steel butterfly valve motorized butterfly valve

Model
Nature of the Manufacturer
Other
Product Category
Butterfly Valve
Place of Origin
City, Province
Overview
1. Beautiful appearance, compact structure, high precision, large output torque, service life is not less than 70,000 times.2. The actuator and valve can be assembled from multiple angles, which is convenient for users to allocate space.3. Ball valve adopts floating soft seal structure, no drip leakage, suitable for heavy dirt and long-term no action occasions.4. Protection grade IP67, can be used in relatively humid environment.
Product Details
Technical parameters
Valve size
BSP/NPT 1/4''
Maximum working pressure
1.0MPa
Circulation medium
Fluid、air
Working voltage
DC12V DC24V DC12-24V AC/DC110-230V
Wiring diagram
CR201 CR202 CR301 CR303 CR306 CR501 CR502 CR702 CR703 CR706 (optional)
Working current
≤1.5A
Openiclose time
≤12S
Life time
70000times
Valve body material
SS304 SS316 (optional)
Actuator material
PPO
Actuator rotation
90°
Torque force
15N.m
Cable length
0.5M 1.5M (optional)
Environment temperature
-15℃-50℃
Liquid temperature
2℃-55℃
Manual override
Yes
Open/close indicator
Yes
Protection class
IP67
Connection standard
ISO5211 F03 F05
Output shaft specifications
9*9 11*11
The assembly diagram
The wiring diagram

1.RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place, the valve remains fuly closed position.

2.BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place,the valve remains fully open position.

*Suitable Working Voltage: DC5V,DC12V,DC24V

*Exceeding the working voltage is forbidden

1.RD & GR connect with positive, BK connect with negative.

2.When OPEN( RD) & SW connected, the valve OPEN, the actuator automatically power off after in place, valve remains fully open position.

3.When CLOSE(GR) & SW connected, the valve CLOSED, the actuator automatically power off after in place, valve remains fully closed position.

*Suitable Working Voltage: DC5V,DC12V,DC24V,AC/DC9-24V

*Exceeding the working voltage is forbidden


1.RD& GR connect with positive, the BK connect with negative.

2.SW CLOSED, the valve OPEN, the actuator automatically power off after in place.

3.SW OPEN, the valve CLOSED, the actuator automatically power off after in place.

*Suitable Working Voltage: AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

1.RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place.

2.BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place.

3.GR & WT connect with the valve's fully open signal wiring.

4.YW & WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:DC5V,DC12V,DC24V

*Exceeding the working voltage is forbidden

1.RD connect with positive.

2. GR connect with SW and negative wiring.

3.BK connect with negative wiring.
4.When SW close.
the valve OPEN, and keeping fully open .

5.When SW open. the valve CLOSED, and keeping fully closed.

6. BL & GY connect with the valve's fully open signal wiring .

7.YW & WT connect with the valve's fully closed signal wiring .

*Suitable Working Voltage: DC9-24V

*Exceeding the working voltage is forbidden

*Feedback with load ability:

①The Max. off voltage: DC36V, AC220V

②The Max. off current:≦0.4A

1.RD& GR connect with positive, the BK connect with negative.

2.SW CLOSED, the valve OPEN, the actuator automatically power off after in place.

3.SW OPEN, the valve CLOSED, the actuator automatically power off after in place.

4.BL & GY connect with the valve's fully open signal wiring.

5.Yw & WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage: AC/DC9-24V.AC110-230V

*Exceeding the working voltage is forbidden

1.When SW is closed, the valve OPEN. the actuator automatically power off after in place.

2.When SW is open, the valve CLOSED, the actuator automatically power off after in place.

*Suitable Working Voltage: AC/DC9-24V AC110-230V

*Exceeding the working voltage is forbidden

1.RD& GR connect with positive, the BK connect with negative.

2.SW CLOSED, the valve OPEN, the actuator automatically power off after in place.

3.SW OPEN, the valve CLOSED, the actuator automatically power off after in place.

4.When extemal power off, the valve OPEN, the actuator automatically power off after in place.

*Suitable Working Voltage: AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

1.When SW is closed, the valve OPEN. the actuator automatically power off after in place.

2.When SW is open, the valve CLOSED, the actuator automatically power off after in place.

3.GR & WT connect with the valve's fully open signal wiring.

4.YW & WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage: AC/DC9-24V, AC/DC110V-230V

*Exceeding the working voltage is forbidden

1.RD & BK are connected to the power, BL & GY are connected to the controlled wiring.

2.When the SW is closed, the valve open.

3.When the SW is open, the valve closed.

4.GR & WT connect with the valve's fully OPEN signal wiring.

5.YW & WT connect with the valve's fully CLOSED signal wiring.

*Suitable Working Voltage: AC/DC110V-230V

*Exceeding the working voltage is forbidden

1.RD & GR connect with positive, the BK connect with negative.

2.SW CLOSED, the valve OPEN, the actuator automatically power off after in place.

3.SW OPEN, the valve CLOSED, the actuator automatically power off after in place.

4. When external power off, the valve closed, the actuator automatically power off after in place.

5.BL & GY connect with the valve's fully open signal wiring.

6.YW & WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage: AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

1.RD & GR connect with positive, the BK connect with negative.

2.SW CLOSED, the valve OPEN, the actuator automatically power off after in place .

3.SW OPEN, the valve CLOSED, the actuator automatically power off after in place.

4. When external power off, the valve open, the actuator automatically power off after in place.

5.BL & GY connect with the valve's fully open signal wiring.

6.YW & WT connect with the valve's fully closed signal wiring.

* Suitable Working Voltage: AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

Tutorial video
Similar Product Recommend