Nominal pressure 350 bars. Maximum pressure 400 bars
The A4VSO or AAVSO Axial piston pump in swash plate design for hydrostatic drives in open circuit operation
– The flow is proportional to the input drive speed and displacement. By adjusting the swash plate angle it is possible to infinitely vary the output flow.
– Excellent suction characteristics
– Low noise level
– Long service life
– Modular design
– Short response times
– Wide range of through drive options
– Visual swivel angle indicator
– Optional mounting position
Technical Data
Table of values (theoretical values, without efficiency and tolerances; values rounded)
Nominal size
A4VSO71
A4VSO125
A4VSO180
A4VSO250
Nominal pressure
p N
bar
350
350
350
350
Maximum pressure
pmax
bar
450
450
450
450
Displacement
Vg max
cm³
71
125
180
250
Speed
Max. speed
nmax
rpm
2200
1800
1800
1500
Flow
at n max
qV max
l/min
156
225
324
375
Power
Δ p = 350 bar
Pmax
kW
91
131
189
219
Torque
Δ p = 350 bar
Tmax
Nm
395
696
1002
1391
Weight (approx.)
m
kg
53
88
102
184
Nominal size
A4VSO355
A4VSO500
A4VSO750
A4VSO1000
Nominal pressure
p N
bar
350
350
350
350
Maximum pressure
pmax
bar
450
450
450
450
Displacement
Vg max
cm³
355
500
750
1000
Speed
Max. speed
nmax
rpm
1500
1320
1000
Flow
at n max
qV max
l/min
533
660
1000
Power
Δ p = 350 bar
Pmax
kW
311
385
525
583
Torque
Δ p = 350 bar
Tmax
Nm
1976
2783
4174
5565
Weight (approx.)
m
kg
207
320
460
605
Operating viscosity range
Within the operating viscosity range between 80…450 SUS (16…100 mm2/s) the units can be operated without limitations of the technical data. In order to obtain optimum efficiency and service life, we recommend that the operating viscosity (at operating temperature) be selected in the range
Installation notes
Optional. The pump case must be filled with fluid during commissioning and remain full when operating.
In order to reduce the operating noise level, all connecting lines (suction, pressure and case drain lines) must be de-coupled from the tank, using flexible elements. The use of check valves in the case drain line must be avoided.
The case drain line must be returned directly to tank without a reduction in cross section.