Control device: (HW) Proportional control hydraulic, mechanical servo, hexagon shaft with lever to the rear.
(EP) Proportional control electric, with emergency actuation and spring return.
For the drum drive in concrete mixers A4VTG071, A4VGT090 series.
–Variable axial piston pump of swash plate design for hydrostatic drives in closed circuit
–The flow is proportional to the drive speed and displacement.
–The flow increases as the angle of the swash plate is adjusted from zero to its maximum value.
–Flow direction changes smoothly when the swash plate is moved through the neutral position.
–Two pressure-relief valves are provided on the high pressure ports to protect the hydrostatic transmission (pump and motor) from overload.
–The high-pressure relief valves also function as boost valves.
–The integrated boost pump acts as a feed pump and control pressure supply.
–The maximum boost pressure is limited by a built-in boost pressure-relief valve.
–Tapered shaft option for direct drive shaft yoke installation.
Technical Data
Table of values (theoretical values, without efficiency and tolerances; values rounded)
Rexroth A4VTG
A4VTG71
A4VTG90
Displacement
Variable pump
Vg max
cm3
71
90
auxiliary pump
Vg H
cm3
18,7
25,7
Speed
Max. speed at Vg max
Nmax continuous
rpm
3300
3050
Limited max.
Nmax limited
rpm
3600
3300
Intermittent max.
Nmax continuous
rpm
4100
3800
minimum speed
Nmin
rpm
500
500
Flow
at Nmax Dauer and Vg max
Qmax
L/min
234
275
Power
at Nmax Dauer D p = 400 bar
Pmax
kW
156
183
Torque
at Vg max D p = 400 bar
Tmax
Nm
451
572
(Variable pump without aux. pump) D p = 100 bar
T
Nm
112,8
143
Moment of inertia (about drive axis)
J
kgm2
0,0072
0,0106
Hydraulic fluid
Before starting project planning, please refer to our data sheets RE 90220 (mineral oil) and RE 90221 (environmentally acceptable hydraulic fluids) for detailed information regarding the choice of hydraulic fluids and application conditions.
The variable pump A4VTG is not suitable for operation with HFA, HFB and HFC. If HFD or environmentally acceptable hydraulic fluids are being used, the limitations regarding technical data and seals must be observed.
The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in a closed circuit the circuit temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range (νopt), see shaded area of the selection diagram. We recommended that the higher viscosity class be selected in each case.
Example: At an ambient temperature of X °F (X °C), an operating temperature of 140 °F (60 °C) is set in the circuit. In the optimum operating viscosity range (νopt shaded area), this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68. The case drain temperature, which is affected by pressure and speed, is always higher than the circuit temperature. At no point of the component may the temperature be higher than 240 °F (115 °C), however. The temperature difference specified below is to be taken into account when determining the viscosity in the bearing.
Shaft seal ring
The service life of the shaft seal ring is affected by the speed of the pump and the case drain pressure. It is recommended
that the average, continuous case drain pressure 45 psi (3 bar) absolute at operating temperature not be exceeded (maximum permissible case drain pressure 90 psi (6 bar) absolute at reduced speed, see diagram). Short-term (t < 0.1 s) pressure spikes of up to 145 psi (10 bar) absolute are permitted. The service life of the shaft seal ring decreases with an increase in the frequency of pressure spikes. The case pressure must be equal to or greater than the external pressure on the shaft seal ring.
Control deviceHW – Proportional control hydraulic, mechanical servo
The output flow of the pump can be steplessly varied in the range between 0 to 100 %, proportional to the rotation of the control lever between 0° and ±29°. A feedback lever connected to the stroke piston maintains the pump flow for any given position of the control lever between 0° and 29°.
The maximum required torque at the lever is 15 lb-in (170 Ncm). To prevent damage to the HW control unit, a positive mechanical stop must be provided for the HW control lever.
Control deviceEP – Proportional control electric
The output flow of the pump can be steplessly varied in the range between 0 to 100 %, proportional to the electrical current supplied to solenoid a or b.
The electrical energy is converted into force acting on the control piston. This control piston then directs control hydraulic fluid into and out of the stroke cylinder to adjust pump displacement as required.
A feedback lever connected to the stroke piston maintains the pump flow for any given current within the control range.
Details model of Rexroth A4VTG71 & Rexroth A4VTG90 pump