Control devices: LAOH2, LAOK, LAOKS, LAOKH1, LAOKH2, LAOKH3, LA1H2, LA1S, LA1K, LA1KS, EP, LA1KH1, etc.
Nominal pressure 350 bars. Peak pressure 400 bars
– Variable double pump A8VO with two axial tapered piston rotary groups of bent-axis design for hydrostatic drives in open circuits
– The flow is proportional to the input speed and to the displacement, and is infinitely variable from qV max to qV min = 0
– The pump is suitable for direct mounting on the flywheel case in diesel engines
– One common suction port for auxiliary pump and both circuits
– A wide range of control instruments is available for different control and regulating functions
– Individual power controller
– Integrated auxiliary pump with pressure-relief valve, optionally with additional pressure-reduction valve
– Power take-off for mounting axial piston and gear pumps
– Excellent power to weight ratio
– Long service life
Product Introduction:
Model: A8VO
Open circuit
Series 61 / 63
Control devices: LAOH2, LAOK, LAOKS, LAOKH1, LAOKH2, LAOKH3, LA1H2, LA1S, LA1K, LA1KS, EP, LA1KH1, etc.
Nominal pressure 350 bars. Peak pressure 400 bars
Technical Data
Table of values (theoretical values, without efficiency and tolerances; values rounded)
Size
A8VO55
A8VO80
A8VO107
A8VO140
A8VO200
Displacement
Vg max
cm3
2 x 54.8
2 x 80
2 x 107
2 x 140
2 x 200
Vg min
cm3
0
0
0
0
0
Gear ratio i = ninput/nrotary groups
1
1
1
1
1
Input speed at Vg max 1)
nmax 1
rpm
2500
2240
2150
2100
1950
at Vg ≤ Vg max2)
nmax
rpm
3000
2750
2450
2450
2250
Flow at nmax and Vg max
qv max
L/min
2 x 137
2 x 179
2 x 230
2 x 294
2 x 390
Power at nmax, Vgmax and Dp=350 bar
Pmax
kW
160
209
268
294 3)
325 3)
Input torque
Tmax
Nm
611
891
1192
1337 3)
1592 3)
Rotary stiffness (single rotary group)5)
cTW
Nm/rad
11213
17985
25565
41408
39505
cTW
Nm/rad
41442
67666
89381
146677
156876
Moment of inertia for rotary group
JTW
kgm2
0.0161
0.0209
0.0345
0.0581
0.0849
without power take-off (PTO)
JTW
kgm2
0.0126
0.0173
0.0288
0.05
0.075
Angular acceleration (single rotary group)5)
a
rad/s2
25800
21800
17100
7500
11000
Mass approx.
m
kg
82
90
116
146
180
Variation: with integrated auxiliary pump, F00, F.. 4)
Displacement with integrated auxiliary pump
Vg max
cm3
8.6
8.6
8.6 (10.7)
10.7
11 (19)4)
Effective displacement
Vg max/eff
cm3
9.7
9.7
11 (13.7)
12.7
13.6 (23.6)
Gear ratio i = ninput/naux. pump
0.887
0.887
0.78
0.843
0.804
Variation: with power take-offs, K.., F.
Max. torque at PTO
Tmax
Nm
250
350
380
450
650
Gear ratio i = ninput/nPTO
1
1
1
1
0.804
1) The values shown are valid for absolute pressure (pabs) of 1 bar at suction port S and for operation with mineral fluids with a specific mass of 0.88kg/L.
2) The values shown are valid for Vg ≤ Vg max or for an increase in the inlet pressure pabs at the suction port S.
3) Observe max. Permissible torque!
4) Available on request
Hydraulic fluid
Before starting project planning, please refer to our data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90223 (HF hydraulic fluids) for detailed information regarding the choice of hydraulic fluids and application conditions.
The A8VO variable double pump is not suitable for operation with HFA. If HFB, HFC and HFD or environmentally acceptable hydraulic fluids are being used, the limitations regarding technical data and seals mentioned in RE 90221 and RE 90223 must be observed.
Details regarding the choice of hydraulic fluid
The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature, in an open circuit the tank temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range (νopt.) – The shaded area of the selection diagram. We recommended that the higher viscosity class be selected in each case. Example: At an ambient temperature of X°C, an operating temperature of 60°C is set. In the optimum viscosity range (νopt., shaded area) this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68. Note: The case drain temperature, which is affected by pressure and speed, is always higher than the tank temperature. At no point in the system may the temperature be higher than 115°C. If the above conditions cannot be maintained due to extreme operating parameters, please contact us.
Case drain fluid
The case drain chamber is connected to the suction and gear chambers. A case drain line to the tank is not required. Note the special feature of size 200 for flushing fluid.
External flushing fluid connection
All A8VO variable double pumps in size 200 always require an external flushing fluid connection from the R4 port to the tank, to ensure cooling and lubrication of the bearing sets. This line should have an internal diameter ≥ 15 mm.