| Model | UB 4KVA | UB 6KVA | UB 7KVA | UB 8KVA | UB 10KVA | UB 15KVA | UB 20KVA | UB 25KVA | UB 30KVA |
| Rated Power | 3.2KW | 4.8KW | 5.6KW | 6.4KW | 8KW | 12KW | 16KW | 20KW | 24KW |
| Peak Power(20ms) | 9.6KW | 14.4KW | 16.8KW | 19.2KW | 24KW | 36KW | 48KW | 60KW | 72KW |
| Start Motor | 3HP | 4HP | 4HP | 4HP | 5HP | 7HP | 10HP | 10HP | 15HP |
| Battery Voltage | 48 / 96 / 192VDC | 96 / 192 / 384VDC | 192 / 384VDC |
| Built-in Solar Controller Charging Current(Optional) | PWM:10A-60A(48V system); 50A/100A(96V system);50A(192V system) MPPT:10A-100A(48V system);50A/100A(96V system) | PWM:10A-60A(48V system); 50A/100A(96V system);50A/100A(192V system) MPPT:10A-100A(48V system);50A/100A(96V system) |
| Size(L*W*H mm) | 565*300*775 | 725*365*1010 |
| Package Size(L*W*H mm) | 625*360*895 | 785*425*1135 |
| N.W.(KG) | 65 | 73 | 75 | 80 | 112 | 134 | 160 | 176 | 189 |
| G.W.(KG) | 78 | 86 | 88 | 93 | 136 | 158 | 184 | 200 | 213 |
| Installation Method | Tower |
| Model | UB 40KVA | UB 50KVA | UB 60KVA | UB 80KVA | UB 100KVA | UB 125KVA | UB 150KVA | UB 200KVA |
| Rated Power | 32KW | 40KW | 48KW | 64KW | 80KW | 100KW | 120KW | 160KW |
| Peak Power(20ms) | 96KW | 120KW | 144KW | 192KW | 240KW | 300KW | 360KW | 480KW |
| Start Motor | 15HP | 20HP | 25HP | 30HP | 40HP | 50HP | 60HP | 80HP |
| Battery Voltage | 192 / 384VDC | 384VDC |
| Built-in Solar Controller Charging Current(Optional) | PWM: 100A-200A(192V / 384V system) / MPPT: 50A-100A(192V / 384V system) | PWM: 100A - 200A / MPPT: 50A / 100A |
| Size(L*W*H mm) | 720*575*1275 | 875*720*1380 | 1123*900*1605 |
| Package Size(L*W*H mm) | 785*640*1400 | 980*825*1560 | 1185*960*1750 |
| N.W.(KG) | 287 | 307 | 337 | 355 | 512 | 552 | 612 | 705 |
| G.W.(KG) | 320 | 340 | 370 | 388 | 552 | 592 | 652 | 755 |
| Installation Method | Tower |
| Input | DC Input Voltage Range | 10.5-15VDC(Single Battery Voltage) |
| AC Input Voltage Range | 380Vac / 400Vac ± 10%(Customized 190Vac/200Vac) |
| AC Input Frequency Range | 45Hz~65Hz |
| Max AC Charging Current | 0~45A(Depending on the Model) |
| AC Charging Method | Three-stage (Constant Current, Constant Voltage, Floating Charge) |
| Phase | 3 / N / PE |
| output | Efficiency(Battery Mode) | 85% |
| Output Voltage(Battery Mode) | 380Vac / 400Vac ± 10%(Customized 190Vac / 200Vac) |
| Output Frequency(Battery Mode) | 50 / 60Hz ± 1% |
| Output Wave(Battery Mode) | Pure Sine Wave |
| Efficiency(AC Mode) | >99% |
| Output Voltage(AC Mode) | Conforming to AC Input |
| Output Frequency(AC Mode) | Conforming to AC Input |
| Output Waveform Distortion(Battery Mode) | ≤3%(Linear Load) |
| No Load Loss(Battery Mode) | ≤1% Rated Power |
| No Load Loss(AC Mode) | ≤2% Rated Power(Charger Does not Work in AC Mode) |
| No Load Loss(Energy Saving Mode) | ≤10W |
| Phase | 3 / N / PE |
Battery Type (Optional) | UO: Gel U.S.A | Charge Voltage:14V; Float Voltage:13.7V (Single Battery Voltage) |
| U1: A.G.M.1 | Charge Voltage:14.1V; Float Voltage:13.4V(Single Battery Voltage) |
| U2: A.G.M.2 | Charge Voltage:14.6V; Float Voltage: 13.7V(Single Battery Voltage) |
| U3: Sealed Lead Acid | Charge Voltage:14.4V; Float Voltage:13.6V(Single Battery Voltage) |
| U4: Gel European | Charge Voltage:14.4V; Float Voltage:13.8V(Single Battery Voltage) |
| U5: Open lead Acid | Charge Voltage:14.8V; Float Voltage:13.5V(Single Battery Voltage) |
| U6: Calcuim(Open) | Charge Voltage: 15.1V; Float Voltage:13.6V(Single Battery Voltage) |
| U7: Sulphation Cycle | 15.5V for 4hrs |
| Customize Battery | Charge and Discharge Parameters of Different Types of Batteres(Such as Lithium Batteries,etc.) Can be Customized According to User Requirements. |
| Protection | Battery Undervoltage Alarm | 11V (Single Battery Voltage) |
| Battery Undervoltage Protection | 10.5V (Single Battery Voltage) |
| Battery Overvoltage Alarm | 15V (Single Battery Voltage) |
| Battery Overvoltage Protection | 17V (Single Battery Voltage) |
| Battery Overvoltage Recovery Voltage | 14.5V (Single Battery Voltage) |
| Overload Power Protection | Automatic Protection (Battery Mode, Circuit Breaker or Insurance (AC Mode) |
| Inverter Output Short Circuit Protection | Automatic Protection (Battery Mode, Circuit Breaker or Insurance (AC mode) |
| Temperature Protection | >90℃(Shut Down Output) |
| Alarm | A | Normal Working Condition, Buzzer has No Alarm Sound |
| B | Buzzer Sounds 4 Times Per Second When Battery Failure,Voltage Abnormality, Overload Protection |
| C | When the Machine is Turned on for the First Time, The Buzzer will Prompt 5 When the Machine is Normal |
Inside Solar controller (Optional) | Charging Mode | MPPT or PWM |
| Charging Current | PWM: 10A / 20A / 30A / 40A / 50A / 60A (48V system); 50A / 100A / 150A / 200A (96V/192V/384V system) MPPT: 10A / 20A / 30A / 40A / 50A / 60A / 80A / 100A (48V system); 50A / 100A (96V/192V/384V system) |
| PV Input Voltage Range | PWM: 60V-88V (48V system); 120V-176V (96V system); 240V-352V (192V system); 480V-704V (384V system) MPPT: 60V-120V (48V system); 120V-240V (96V system); 240V-360V (192V system); 480V-640V (384V system) |
Max PV Input Voltage (At the Lowest Temperature) | PWM: 100V (48V system); 200V (96V system); 400V (192V system); 750V (384V system) MPPT: 150V (48 system); 300V (96V system); 450V (192V system); 750V(384V system) |
| PV Array Maximum Power | 48V system: 560W / 1120W / 168OW / 2240W / 2800W / 3360W / 448OW / 5600W; 96V system: (PWM: 5.6KW / 11.2KW) / (MPPT: 5.6KW / 5.6KW*2); 192V system: (PWM: 11.2KW / 22.4KW / 16.8KW*2 / 22.4KW*2) / (MPPT: 11.2KW / 11.2KW*2); 384V system: (PWM: 22.4KW / 44.8KW / 33.6KW*2 / 44.8KW*2) / (MPPT: 22.4KW / 22.4KW*2) |
| Standby Loss | ≤3W |
| Maximum Conversion Efficiency | >95% |
| Working Mode | Battery First / AC First / Saving Energy Mode |
| Transfer Time | ≤4ms |
| Display | LCD |
| Thermal Method | Cooling Fan in Intelligent Control |
| Communication(Optional) | RS232 / RS485 / APP (WIFH/GPRS) |
| Environment | Operating Temperature | -10℃ ~ 40℃ |
| Storage Temperature | -15℃ ~ 60℃ |
| Noise | ≤65dB |
| Elevation | 200m (More Than Derating) |
| Humidity | 0%~95% (No Condensation) |
| Warranty | 1 Year |
Note: 1.Specifcations are subject to change without prior notice; 2.Special voltage and power requirements can be customized according to the actualsituation of users. |