Fan condition monitoring system

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
FanconditionmonitoringandfaultdiagnosissystemConditionmonitoringisthemeasurementandanalysisofdatasuchasvibration
Product Details
Fan condition monitoring and fault diagnosis system
Condition monitoring is the measurement and analysis of data such as vibration, air gap, temperature, power, current, and lubricating oil status, and it can monitor the status of equipment components (transmission, bearings, shafts, gears, rotors, and other components) , Vibration and process parameters (such as shaft vibration, intensity, tile vibration, eccentricity, differential expansion, shaft displacement, thermal expansion, speed and temperature), these data show specific and important waveform diagrams and damage characteristics in the frequency spectrum. Based on the monitoring results, faults and emerging wear can be detected and eliminated in advance; complete shutdowns, suspensions and subsequent subsequent damage can be avoided.
 
● Monitor equipment operating status and control equipment health status;
● Analyze equipment operation trends and predict possible equipment failure;
● Reduce maintenance and upkeep cycles to avoid, slow down and reduce accidents;
● Provide a scientific basis for online adjustment and shutdown of equipment.
 
Case 1: Cost-effective vibration measurement, which can remotely monitor the vibration of the pump and output an alarm signal.
● Eliminate manual site inspections;
● The pump abnormality is found very early and an alarm signal is output.
 
Case two: comprehensively monitor the working status of the pump and diagnose the fault location.
● Eliminate manual site inspections;
● The pump abnormality is detected very early and an alarm signal is output;
● Diagnose the fault location;
● Output equipment management and maintenance reports;
● On-site dynamic balance analysis and calculation.