Features:
An eddy current sensor is a non-electrical electrical measuring device capable of converting mechanical displacement or vibration amplitude into electrical signal output. It consists of a probe (sensor), an extension cable, and a converter (front end). It has the advantages of wide frequency response, wide linear measurement range, small size, strong anti-interference ability, convenient installation and use, and long-term continuous and stable work. In particular, it has the characteristics of non-contact measurement, which will facilitate the dynamic measurement of rotating bodies such as rotating shafts, and the probe can work in water, oil and other media.
● Non-contact measurement
● Simple structure
● Frequency response
● High sensitivity and high resolution
● Strong anti-interference ability
● Large measurement linear range
Main Specifications:
Range | 0-2mm |
Sensitivity and error ( mV / μm ) | Not interchangeable | 4 ± 10% mV / μm |
Mutual exchange | 4 ± 15% mV / μm |
Resolution | 1μm |
Linearity and error | Not interchangeable | ≤2% |
Mutual exchange | ≤5% |
Frequency response | 0 to 5 kHz |
Temperature sensitivity error | 0.1% / ℃ FS |
Operating temperature | Probe head | -30~150 ℃ |
Front end | -20~65 ℃ |
Initial clearance | 0.1~0.5mm |
Probe specifications | Probe diameter | φ8 |
Mounting thread | M10 × 1 |
Probe length | 60mm |
cable length | 2 meters |
Test Conditions | Power source | -24VDC |
Test material | 45 #钢 |
Ambient temperature | 20 ± 5 ℃ |
Relative humidity | ≤80% |
Accessories | One protective cap, two nuts M10 × 1 |