Features:
● Wide frequency response and wide temperature range
● Small size and strong anti-interference ability
● Non-contact measurement, large linear range
● Simple structure and easy installation and use
● Particularly suitable for testing rotating machinery
● The probe can work in water, oil and other media
● High sensitivity and high resolution
Main Specifications:
Note: The test conditions for all indicators below are 45 # steel (equivalent to AISI 4145 steel), ambient temperature 20 ℃ ± 5 ℃, relative humidity <80%, and power supply -24VDC. The initial gap is 0.8 ~ 2.0mm.
Linear range | 0-10mm |
Linearity and error | Not interchangeable | <5% |
Mutual exchange | <8% |
Sensitivity and error | Not interchangeable | 1 ± 5% mV / μm |
Mutual exchange | 1 ± 10% mV / μm |
Temperature sensitivity error | <0.1% / 0CF.S |
Frequency response | 0-5kHz |
Operating temperature | Probe head | -30 ℃ — + 150 ℃ |
Front end | -20 ℃ —65 ℃ |
Power supply | DC : -24V / 20mA |
Front Dimensions | 80mm (L) ╳60mm (W) ╳30mm (H) |
Front Mounting Dimensions | 50.8mm╳50.8 mm ( 4-Φ4.5mm ) |
Front weight | About 0.2KG |
Input and output mode | Probe output method | L 6 |
Front input method | L 6 |
Front output mode | Terminal block ( T31-OM13-03 ) |
Probe diameter | Φ29mm |
Probe length | 100mm |
Probe mounting dimensions | ( M16╳1.5 ) ╳100mm |
power supply | Terminal block ( T31-OM13-03 ) |
annex | Extension cable: 2 yards L6 RF coaxial cable temperature |