Welcome Customer !

Membership

Zhejiang Top Cloud-Agri Technology Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 土壤检测仪器

Xwboo>Products

Zhejiang Top Cloud-Agri Technology Co., Ltd.Free·1YRS

  • E-mail

  • Phone

    +86(571)86062776

  • Address

    11-12/F, 3/B, No 88, Xiangyuan Road, China Wisdom Information Industry Park Gongshu Dist., Hangzhou, P.R.C 310015

Contact Now

Gas Chromatography GC1290 (EPC & Touchscreen)

Model
Nature of the Manufacturer
Other
Product Category
General Lab Equipment
Place of Origin
City, Province
Overview
Gas Chromatography GC1290 (EPC & Touchscreen)
Product Details

Features:

Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system")
Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening. 450℃ to 50℃ in 6 min at 25℃ ambient)
Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards

Superior performance with advanced, microcomputer-based temperature control system
High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference
Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
Intuitive display of timing program, detector status, measurement range, current setting, etc

Technical Parameters:

ModelsGC1290GC1120
DescriptionEPC
Sample Introduction Systemsample injector and evaporation chamber
Column OvenTemperature rangeAmbient temperature +7 °C ~ 400 °C (in 1 °C increment)
Temperature accuracy± 0.02 °C
Cooling time400 °C to 50 °C in 6 min at 25 °C ambient
Programmed temperature setting0.1 °C 70 °C /min (in 1 °C increment)
FIDDetection limit<3xlO-12g/s(C16)
Drift<6xlO_13A/h
TCDSensitivity> SOOOmVmL/mg
Baseline noise<20^V
FPDDetection limit< 8xlO*13g/s(P); < 8xl041g/s(S)
Drift<2xl0-11.W0min
Baseline noise<5x1042A
ECDDetection limit<2xl0 13g/s(7-666)
Drift< 80gV/30min
Baseline noise<20^V
Linear dynamic range>103
NPDDetection limit< 5xl043g/s(P); < 5xlO_12g/s(N)