This meter is a perfect combination of the most advanced electronic technology, sensor technology, and software design. The meter can measure the parameters of pH, ORP, conductivity, TDS, salinity, resistivity, DO and temperature for high accuracy water solution. It is the best portable water analysis meter with the highest performance and the lowest cost. It is suitable for trade such as the mining industry, power plant, water treatment projects, environmental protection, etc., especially has more extensive application in the field and spot test.
pH | |
Measuring range | (-2.00 to 19.99) pH |
Resolution | 0.1/0.01 pH |
Accuracy | Meter:±0.01pH; Overall: ±0.02pH |
Input current | ≤2×10-12 A |
Input impendance | ≥1×1012 Ω |
Stability | ±0.01 pH/3h |
Temp. compensation range | (0 to 100) ℃ (automatic) |
ORP(mV) | |
Measuring range (mV/ORP/EH) | -1999 mV to 0 to 1999mV |
Resolution | 1mV |
Accuracy | Meter:±0.1% FS, Overall: ±15mV |
Conductivity | |
Measuring range | Conductivity: (0.00 to 19.99)μS/cm (20.0 to 199.9)μS/cm (200 to 1999)μS/cm (2.00 to 19.99) mS/cm (20.0 to 199.9) mS/cm TDS: (0 to 100) g/L Salinity : (0 to 100) ppt Resistivity:(0 to 100) MΩ·cm |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
Accuracy | Meter:±1.0% FS, Overall:±1.5% FS |
Temp. compensation range | (0 to 50) ℃ (automatic) |
Electrode constant | 0.1 / 1 / 10 cm-1 |
Benchmark temperature | 25℃, 20℃and 18℃ |
Dissolved Oxygen | |
Measuring range | (0 to 40.00) mg/L(ppm) (0 to 200.0) % |
Resolution | 0.1/0.01 mg/L(ppm) 1/0.1% |
Accuracy | Meter:±0.10 mg/L, Overall:±0.40 mg/L |
Response time | ≤30 s (25℃, 90% response) |
Residual current | ≤0.1 mg/L |
Temp. compensation range | (0 to 45) ℃ (automatic) |
Salinity compensation range | (0 to 45) ppt (automatic) |
Atmospheric pressure compensation range | (66 to 200) kPa (manual) |
Automatic calibration | Air saturated by water; water saturated by air |
Electrode type | Polarogram type |
Other Technical Parameters | |
Data storage | 400 groups |
Storage content | Series number, measuring value measuring unit and temperature, |
Power | Two AA batteries (1.5V x2) |
Size and weight | (360 x 270x 76) mm/1.7kg |
Working Condition | |
Environment temperature | 5 to 35 ℃ (0.01 grade) |
Environmental humidity | ≤85% |
IP rating | IP57 Dustproof and waterproof |