1. Size Available 2-122. The 7120 series outlet port has the same size with inlet3. The 8120 series outlet port is one size larger than inlet in order to optimize flow capacity4.Pipe away.5. Protective screens are provided at pressure and vacuum port to prevent entrance of other matter6. The flame arrestor, inlet pipe, steam jacket, blowing hole, lining or humidity absorber are options to clients.7. Designed and tested according to API2000.8. The flanges are accordance with ANSI B16.5, EN1092, JIS.9. Available mate......
The 7120/8120 Pressure/Vacuum Relief Valve are designed for being used on atmospheric and low pressure storage tanks, pipe away.
The primary function is to protect tanks from damager deformation, and minimize emmissions to the environment, as well as loss of product due to evaporation.

Setting Pressure /Vacuum |
Setting KPa | 7110/8110 | 7112/8112 | 7113/8113 |
Set pressure | 0.21~6.9 | 0.2~6.9 | 6.9~13.4 |
Set vacuum | -0.2~-4.3 | -4.3~-82 | 0.2~-4.3 |
| 7120/7122/7123/7125 Dimensions,mm |
| Nominal Size | 2X2" | 3X3" | 4X4" | 6X6" | 8X8" | 10X10" | 12X12" |
| L | 345 | 406 | 445 | 546 | 696 | 853 | 995 |
| W Width | 200 | 200 | 230 | 280 | 345 | 406 | 485 |
| H1 | 300 | 359 | 417 | 523 | 648 | 789 | 923 |
| H2 | 412 | 441 | 525 | 660 | 893 | 1055 | 1257 |
| A | 123 | 138 | 153 | 166 | 216 | 273 | 320 |
| B | 200 | 245 | 280 | 350 | 420 | 515 | 590 |
| 8120/8122/8123/8125 Dimensions,mm |
| Nominal Size | 2X3" | 3X4" | 4X6" | 6X8" | 8X10" | 10X12" | 12X14" |
| L | 360 | 435 | 494 | 641 | 798 | 940 | 1116 |
| W Width | 200 | 230 | 280 | 345 | 406 | 485 | 533 |
| H1 | 340 | 402 | 498 | 640 | 744 | 875 | 984 |
| H2 | 422 | 510 | 363 | 884 | 1010 | 1209 | 1253 |
| A | 138 | 153 | 166 | 216 | 273 | 320 | 381 |
| B | 226 | 265 | 327 | 411 | 470 | 542 | 616 |