| Parameter & configration List |
| Item | Subitem | GE8025 | GE6025 | GE6020 | GE4020 | GE3015 |
| Basic parameter | Working area | 8100mm*2500mm | 6100mm*2500mm | 6100mm*2000mm | 4000mm*2000mm | 3000mm*1500mm |
| Table load bearing | 6000kg | 2950kg | 2400kg | 1600kg | 900kg |
| Machine overall dimensions | 19500*3600*2200mm | 15300*3600*2200mm | 15100*3000*2000mm | 10200*3100*2000mm | 9350*2300*2000mm |
| Machine weight | 21000kg | 18000kg | 16000Kg | 10000kg | 5700kg |
| Z axis travel | 120mm | 315mm | 315mm | 315mm | 315mm |
| Fastest exchange time of platforms | 60s | 30s | 30s | 10s | 10s |
| Operation parameter | Max. linkage speed | 140m/min | 140m/min | 140m/min | 140m/min | 140m/min |
| Max. acceleration | 1.5G | 1.5G | 1.5G | 1.5G | 1.5G |
| Positioning accuracy | 0.05mm | 0.05mm | 0.05mm | 0.05mm | 0.03mm |
| Repositioning accuracy | 0.03mm | 0.03mm | 0.03mm | 0.03mm | 0.02mm |
processing precision (1mm Original box carbon steel plate) | Φ30mm roundness | ≤0.1mm | ≤0.1mm | ≤0.1mm | ≤0.1mm | ≤0.1mm |
| 30mm adjacent side dimension difference | ≤0.04mm | ≤0.04mm | ≤0.04mm | ≤0.04mm | ≤0.04mm |
| 190mm adjacent side dimension difference | ≤0.06mm | ≤0.06mm | ≤0.06mm | ≤0.06mm | ≤0.06mm |
| 190mm diagonal size difference | ≤0.07mm | ≤0.07mm | ≤0.07mm | ≤0.07mm | ≤0.07mm |
| Optical system | Laser source | MAX/IPG Raycus/GW | MAX/IPG Raycus/GW | MAX/IPG Raycus/GW | MAX/IPG Raycus/GW | MAX/IPG Raycus/GW |
| laser head | 6KW:WSX/Raytools/Hsns 6KW above:Gemany Precitec | 6KW:WSX/Raytools/Hsns 6KW above:Gemany Precitec | 6KW:WSX/Raytools/Hsns 6KW above:Gemany Precitec | 6KW:WSX/Raytools/Hsns 6KW above:Gemany Precitec | 6KW:WSX/Raytools/Hsns 6KW above:Gemany Precitec |
| Precitec Special Laser Head Equipped with External Water Cooling | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Automatic focusing function of laser head | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Multi-stage perforation Technology | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| smooth cutting technology | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Anti-slag protection function of double cyclones | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| mechanical system | Machine bed | Cast iron bed | Cast iron bed | Cast iron bed | Cast iron bed | Cast iron bed |
| X-axis,Y-axis,Z-axisServo motor and driver | Japan Yaskawa | Japan Yaskawa | Japan Yaskawa | Japan Yaskawa | Japan Yaskawa |
| Slideway | Made in Taiwan | Made in Taiwan | Made in Taiwan | Made in Taiwan | Made in Taiwan |
| Rack | Made in Taiwan | Made in Taiwan | Made in Taiwan | Made in Taiwan | Made in Taiwan |
| Closed protection enclosure | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Automatic lubrication function | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Countertop locking function | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
Intelligent control system
| Control system | Cypcut | Cypcut | Cypcut | Cypcut | Cypcut |
| Display size | 21.5 inches | 21.5 inches | 21.5 inches | 21.5 inches | 21.5 inches |
| WIFI wireless control | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Nozzle automatic calibration function | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Nozzle automatic cleaning function | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
| Process monitoring | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Active obstacle avoidance function | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Laser cutting technology database | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Auxiliary gas low pressure alarm function | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Cutting gas automatic pressure regulation function | 6KW below:O2 6KW and above:O2,N2,air | 6KW below:O2 6KW and above:O2,N2,air | 6KW below:O2 6KW and above:O2,N2,air | 6KW below:O2 6KW and above:O2,N2,air | 6KW below:O2 6KW and above:O2,N2,air |
| Breaker | France Schneide | France Schneide | France Schneide | France Schneide | France Schneide |
| Relay | France Schneide | France Schneide | France Schneide | France Schneide | France Schneide |
| Electrical proportional valve | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS |
| O2 Cutting gas control valve | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS |
| N2 Cutting gas control valve | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS | Germany AVENTICS |
| System identification file format | G file,DXF,PLT,AI | G file,DXF,PLT,AI | G file,DXF,PLT,AI | G file,DXF,PLT,AI | G file,DXF,PLT,AI |
| Safety protection system | Large enclosure open door protection | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Laser abnormal alarm | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Cutting abnormal alarm | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Gas low pressure alarm | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Water cooler abnormal alarm | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Laser protective glasses | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Peripheral system | Water cooler | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Dust removal | Centrifugal fan | Centrifugal fan | Centrifugal fan | Centrifugal fan | Centrifugal fan |
| Other parameters configuration | Integral aluminum cantilever for high pressure steel mould casting | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Total power/current with30KW source | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Total power/current with 20KW source | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Total power/current with 15KW source | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Total power/current with 12KW source | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Total power/current with 8KW IPG source | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| Total power/current with 6KW source | 51kW/121A | 41kW/97A | 44.9kW/106.6A | 41.9kW/99.5A | 37kW/88A |
| Total power/current with 3KW source | 43.2kW/102.6A | 33.2kW/78.9A | 32.5kW/77.2A | 29.5kW/70.1A | 24kW/58A |
| Total power/current with 2KW source | 39.5kW/93.8A | 29.5kW/70.1A | 28.8kW/68.4A | 25.8kW/61.3A | 21kW/49A |
| Total power/current with 1.5KW source | 37.5kW/89.1A | 27.5kW/65.3A | 26.8kW/63.7A | 23.8kW/56.6A | 19kW/45A |
| Total power/current/current with 4KW source | 36.3kW/86.2A | 26.3kW/62.5A | 25.6kW/60.8A | 22.6kW/53.7A | 18kW/42A |
| Multifunctional ergonomic handle | standard configuration | standard configuration | standard configuration | standard configuration | standard configuration |
| Option | laser fume filter(Made in China) | 1set | 1set | 1set | 1set | 1set |
| laser fume filter(America Donaldson) | DFOE6-1 set | DFOE6-1 set | DFOE6-1 set | DFOE6-1 set | DFOE4-1 set |
security light curtains Generally, 1 set, large equipment or have special requirements, and other non-standard.(CE and ETL certification standard) | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
| electron microscope | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
G-Lift It is used for auxiliary loading of the backboard and can be equipped with 1 set for each equipment. | No configuration required | No configuration required | No configuration required | No configuration required | optional configuration |
| Automatic loading system | No configuration required | No configuration required | No configuration required | No configuration required | optional configuration |
| Integrated compressed air system | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
| Voltage regulator | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
Laser case plus air conditioner Generally no air conditioning is required, and it is optional in the tropics. | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
| 6KW Equipped with Gemany Precitec Laser Head | optional configuration | optional configuration | optional configuration | optional configuration | optional configuration |
| Precitec laser head added laser head side blow module | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |
| 150mm focus distance Precitec laser head | No configuration required | No configuration required | No configuration required | No configuration required | No configuration required |