Short Description: 7-channel flow-through cell dissolution apparatusMedium heating and stirring apparatusAutomatic sampling workstationAccurate medium preheating temperature control function Model: RCY-SZRT-RT7 Weight: 0-100Kg
Introduction
RT7 flow-through cell dissolution system includes: seven channel flow-through cell dissolution apparatus, medium heating and stirring apparatus, automatic sampling workstation. A set of RT7 dissolution system can meet the experimental requirements of open-loop method and closed-loop method, and has advanced functions such as automatic change of medium, automatic change of flow rate and automatic sampling.
Composition
*RT7 Medium Heating and Stirring Apparatus
Accurate medium preheating temperature control function, evenly preheat the medium to the specified temperature. After preheating, the medium enters the flow-through cell after the secondary temperature control by the thermostatic coil in the flow-through cell apparatus. Ensure that the temperature of the medium entering the flow-through cell is more accurate and uniform.
The 8-position magnetic stirring device can meet the experimental requirements of 7 sample medium, vessels+1 replenishment medium vessel in closed-loop mode.
The automatic changing medium module can be selected to realize the automatic changing of various mediums in the dissolution test process using the open-loop mode.
*RT7 Automatic Sampling Workstation
A single automatic sampling workstation integrates the functions of closed-loop sampling and pen-loop sampling at the same time, and the switching between the two sampling modes is very convenient.
In open-loop mode, interval sampling, continuous sampling or split ratio sampling can be selected.
The sample holders suitable for 300mL sample vessel, 10mL test tube and liquid phase vial.
Teflon pipe with high chemical stability and high adsorption resistance is adopted. Effectively avoid adsorption and residue.





Technical Data
| System Components | Technical Parameter |
Flow-through Cell Dissolution Apparatus | Number of channels: 7 |
| It can be adapted to various flow-through cell. |
| The temperature is adjustable, and the temperature control error is less than 0.2°C. |
| The temperature difference between the cell is within the rang of setting value ±0.5°C. |
| The velocity is ad adjustable, and the velocity error is less than ±5%. |
| Pulsation mode (120Hz) or no pulsation mode can be selected for flow rate mode. |
| Both open-loop mode and closed-loop mode are available. |
Medium Heating and Stirring Apparatus | The temperature is adjustable, and the temperature control error is less than 0.5°C. |
| The stirring speed is adjustable. |
| The stirring working position: 8. |
| Both open-loop mode and closed-loop mode are available. |
Automatic Sampling Workstation | Number of channels: 7 |
| It can be adapted to 300 ml sample bottle. 10ml test tube and liquid phase vial. |
| Both open-loop mode and closed-loop mode are available. |
| In open-loop mode, interval sampling, continuous sampling or split ratio sampling are available. |