MODEL | BG-30-12 | BG-30-24 | BG-30-36 | BG-30-48 |
OUTPUT | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 2.5A | 1.25A | 0.84A | 0.63A |
Current range | 0 ~ 2.5A | 0 ~ 1.25A | 0 ~ 0.84A | 0 ~ 0.63A |
Rated power | 30W | 30W | 30.3W | 30.3W |
Ripple & noise | 80mVp-p | 100mVp-p | 100mVp-p | 120mVp-p |
Setup,rise,hold time | 500ms, 20ms,20ms/230VAC |
INPUT | Voltage range | 85~264VAC 120~370VDC |
Frequency range | 47 ~ 63Hz |
Efficiency | 84% | 84% | 85% | 85% |
Ac current | 0.8A/115VAC 0.4A/230VAC |
Inrush current | Cold start 30A |
Leakage current | <0.5mA/240VAC |
PROTECTION | Overload | 115 ~ 150% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage | 5.8~6.8V | 28~32V | 28~32V | 55~64V |
Protection type :Shut off |
ENVIRONMENT | Working temp,humidity | -20℃ ~ +60℃,20% ~ 90% RH non-condensing |
Storage temp,humidity | -20℃ ~ +85℃,10% ~ 95% RH non-condensing |
Withstand vibration | 10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes |
SAFETY & EMC | Safety standard | Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved |
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMC standard | EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved |
OTHERS | MTBF | 500K hrs |
Dimension | 222*30*20mm (L*W*H) |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |