Model | SC-60-12 | SC-60-24 |
OUTPUT | DC voltage | CH1:13.8V | CH1:13.4V | CH1:27.6V | CH2:26.5V |
Voltage tolerance | ±1% | ----- | ±1% | ----- |
Rated current | 4.0A | 0.35A | 2.0A | 0.25A |
Current range | 0~4A | ----- | 0~2A | ----- |
Rated power | 59.9W | 61.8W |
Ripple&noise | 100mvp-p | ----- | 100mvp-p | ----- |
DCvoltage ADJ.range | CH1:11.3~14.9V | CH1:21.3~29.8V |
INPUT | Voltage range | 90~264VAC,127~370VDC |
frequency | 47~63HZ |
AC current | 1.6A/115VAC,0.8A/230VAC |
efficiency | 81% | 83% |
Inrush current | Cold start current 25A/115VAC,45A/230VAC |
Leakage current | < 1mA/240VAC |
PROTECTION | Over load | Rated output power110%~150% start over load protection |
protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed |
Battery protection | 9.5~11V | 20~22V |
At low voltage | protection mode:cutoff output |
FUNCTION | UPS introduction | long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop harging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard, |
cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs |
ENVITONMENT | Working temp,humidity | -10°C~+60°C,20%~90%RH |
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing |
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
SAFETY | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
OTHERS | Dimension | 129*98*38mm(L*W*H) |
Weight/packing | 0.52kg |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |