Accuracy: Class C/ R160Single-jet, Dry-dial, Magnetic drive, Anti-magnetic ProtectionAvailable for cold water (50°C) and hot water (90°C)Sizes: DN15mm (½" ).Body material: Brass
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
Size | Class | Qs Overload flow | Qp Nominal flow | Qt Transitional flow | Qmin Min flow | Min reading | Max reading |
DN(mm) | Inch | m³/h | L/h | m³ |
15 | 1/2" | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
B | 120 | 30 |
C | 22.5 | 15 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE | Mm Inch | 15 1/2" |
Q4(m³/h) | 3.125 |
Q3(m³/h) | 2.5 |
R80 | Q2(L/h) | 50 |
Q1(L/h) | 31.25 |
R100 | Q2(L/h) | 40 |
Q1(L/h) | 25 |
R125 | Q2(L/h) | 32 |
Q1(L/h) | 20 |
R160 | Q2(L/h) | 25 |
Q1(L/h) | 15.625 |
Min reading(m³) | 0.00005 |
Max reading(m³) | 99,999 |
Max pressure(MAP) | 16 |
Max loss(∆ P) | 63 |
Max temperature | T50 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
| Meter size | Length(L) | Width(B) | Height(H) | Connecting Thread | Weight |
| Dia | D | Kg |
| DN | | |
| (mm) | mm | | |
| 15 | 110 | 77 | 80 | G 3/4B | 0.59 |
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.6Mpa