Accuracy: R80 / R100 / Class BMulti jet, Dry-dialMaterial body: Brass.Sizes: DN15 to 20mm, (1/2" – 3/4"), Available for cold water (30°C), hot water(90°C)
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
Meter size Dia DN (mm) | Class | Qs Overload Flow | Qn Nominal Flow
| Qt Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
| m3/h | L/h | m3 |
| 15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 |
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE | Mm Inch | 15 1/2" | 20 3/4" |
Q4(m³/h) | 3.125 | 5 |
Q3(m³/h) | 2.5 | 4 |
R80 | Q2(L/h) | 50 | 80 |
Q1(L/h) | 31.25 | 50 |
Min reading(m³) | 0.00005 | 0.00005 |
Max reading(m³) | 99,999 | 99,999 |
Max pressure(MAP) | 16 | 16 |
Max loss(∆ P) | 63 | 63 |
Max temperature | T50 | T50 |
Pulse output option | Vmax=24V, Imax=100mA, Pmax=2W |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) | Length | Width | Height
| Connecting Thread D | Weight Kg |
| mm |
| 15 | 165 | 99 | 104 | G 3/4B | 1.5 |
| 20 | 190 | 99 | 106 | G 1B | 1.7 |
WORKING CONDITION
Water temperature:≤40℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.6Mpa