Single-jet, Dry-dial, Magnetic drive, Anti-magnetic ProtectionAvailable for cold water (40°C) and hot water (90°C)Sizes: DN15 to 20 mm (½" – 3/4").Body material: BrassAccuracy: Class B or R80Pulse output 10 L/Pulse
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
| Meter size | Class | Qs | Qn | Qt | Qmin | Min | Max |
| Dia | Overload | Nominal | Transitional | Min | Reading | Reading |
| DN | Flow | Flow | Flow | Flow | Lectura | Lectura |
| (mm) | m3/h | L/h | m3 |
| 15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 |
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE | Mm Inch | 15 1/2" | 20 3/4" |
Q4(m³/h) | 3.125 | 5 |
Q3(m³/h) | 2.5 | 4 |
R80 | Q2(L/h) | 50 | 80 |
Q1(L/h) | 31.25 | 50 |
Min reading(m³) | 0.00005 | 0.00005 |
Max reading(m³) | 99,999 | 99,999 |
Max pressure(MAP) | 16 | 16 |
Max loss(∆ P) | 63 | 63 |
Max temperature | T50 | T50 |
Pulse output option | Vmax=24V, Imax=100mA, Pmax=2W |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
| Meter size | Length(L) | Width(B) | Height(H) | Connecting Thread | Weight |
| Dia | D | Kg |
| DN | | |
| (mm) | mm | | |
| 15 | 110 | 80 | 80 | G 3/4B | 0.6 |
| 20 | 130 | 80 | 80 | G 1''B | 0.9 |
WORKING CONDITION
Water temperature:≤40℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.6Mpa