1.DN15, DN202.Communication: M-BUS, RS-485, pulse output for option 3.Accuracy: R1604.Waterproof standard: IP 68
Smart ultrasonic water meter measurement of water consumption in households, apartment buildings and small commercial properties
TECHNICAL SPECIFICATION:
Item | Parameter |
Meter Type | Ultrasonic Water Meter |
Nominal Diameter (mm) | DN15~DN20 |
Q3/Q1 | R160 |
Measured medium | Water, homogeneous liquid, and filled with measured pipes. |
Accuracy class | Class 2 |
Water pressure class | 1.6MAP |
Pressure-loss class | Δp40 |
Temperature class | T50 |
Installation position | H/V |
The installation sensitivity class | U10/D5 |
Electromagnetic class | E1 |
Environmental class | C |
Key-press | Magnetic induction key |
Types of Indicating device | LCD:9-digits, 0~99999.9999m³ |
Menu Contents | Instantaneous flow (m3/h), cumulative flow (m3), screen detection, table address, cumulative working time (h), date (year/month/day), caliber, software version |
Communication Interface | Photoelectric |
Power Source | Lithium battery ER18500(replaceable) |
Battery Voltage &Capacity | 3.6V , 4000mAh |
Life span | 10 years. |
IP code | IP68 |
Storage Temperature | -25℃~+55℃ |
Cable length | 1.0 m |
FLOW RATE:
Parameter | Unit | Data value |
Nominal Diameter | | DN15 | DN20 |
Start flow rate | m3/h | 0.006 | 0.010 |
Qmin(Q1) | 0.015625 | 0.025 |
QTransitional(Q2) | 0.025 | 0.04 |
Qn/permanent(Q3) | 2.5 | 4.0 |
Qoverload(Q4) | 3.125 | 5.0 |
Range ratio=Q3/Q1 | | 160 |
Temperature | | T50 |
Battery life | Year | 10 |
DIMENSION
Nominal Diameter( mm ) | DN15 | DN20 |
Thread | G3/4B | G1B |
L(mm) | 110 | 130 |
H(mm) | 95 | 95 |
W(mm) | 85 | 95 |
WORKING CONDITION:
Water temperature: 0~50℃
Water pressure: ≤16 Bar