1. DN50-DN2002. Communication: M-BUS, RS-485, Modbus, Pulse output, LoRaWAN3. Accuracy: R2004. Frequency: LoRa/ LoRaWAN 868MHz, 915MHz, Customized Frequency Requirement
TECHNICAL SPECIFICATION:
Diameter | Permanent Q3(m³/h) | Transitional Q2(m³/h) | Minimum Q1(m³/h) | Overload Q4(m³/h) |
DN50 | 25 | 0.2 | 0.125 | 31.25 |
DN65 | 40 | 0.320 | 0.2 | 50 |
DN80 | 63 | 0.504 | 0.315 | 78.75 |
DN100 | 100 | 0.8 | 0.5 | 125 |
DN125 | 160 | 1.280 | 0.8 | 200 |
DN150 | 250 | 2 | 1.250 | 312.5 |
DN200 | 400 | 3.2 | 2 | 500 |
Measurement Accuracy | Q2≤Q≤Q4 ±2% Q1≤Q<Q2 ±5% |
Range Ratio | Q3/Q1=200,Q2/Q1=1.6,Q4/Q3=1.25 |
Connection | flanged joint |
Pressure Loss | Δp40 |
Pressure Level | MAP10 or MAP16 |
Data Storage | Data storage for continual 18 months |
Power-off Protection | The data of accumulated flow and corresponding time will be saved once power failure takes place,and the meter works automatically as soon as the power restoration |
Remote Transmission | Standard Infrared,LoRaWAN,M-bus Remote Transmission, RS485(Modbusprotocol),Pulse Output |
Power Supply | Lithium Battery Power Supply/M-BUS Remote Power Supply |
Protection Class | IP68 |
Work Environment | Temperature:-25°C~+55°C, Environment Relative Humidity:<> |
Installation | Horizontal or Vertical |
Service Life | life Time≥6 years |
DIMENSION

Nominal Diameter | L(mm) | H(mm) | W(mm) | Md | Bolt Hole Qty |
DN50 | 200 | 220 | 170 | M16 | 4 |
DN65 | 200 | 240 | 185 | M16 | 4 |
DN80 | 225 | 255 | 250 | M16 | 8 |
DN100 | 250 | 275 | 270 | M16 | 8 |
DN125 | 250 | 305 | 300 | M16 | 8 |
DN150 | 300 | 335 | 330 | M20 | 8 |
DN200 | 350 | 395 | 380 | M20 | 8 |
USER MENU:

VERIFICATION MENU:

WORKINGCONDITION:
Watertemperature: 0~50℃
Waterpressure: ≤16 Bar