SIF Silicone rubber insulation electric wire
Conductor:bare copper, tinned copper
Insulator: silicone rubber
Rated VOLT: 300/500V
Test Voltage:2000V. 5Min
Rated Temp.:-60℃~+180℃
Mechanical properties
Tensile strength: 5N/mm2 min.
Elongation at break of insulation: ≥150%
Min.Bending radius:6×OD
Characteristics:
Silicone rubber wire & cable have very good flexibility and good performance of resistance to high temperature, range from -55℃ up to 180℃.
The use of silicone rubber, a high grade corona resistant insulation material, gives the cable excellent dielectric strength.
Application: Silicone wire & cable are used where high flexibility is required and high temperatuer conditions. It is therefore a suitable connection cable for home electric appliance, high voltage machines like transformers, generators, motors, traction machines.
Spec. | Conductor | Insulation | Wire OD | Conductor resistance Ω/KM |
Structure | OD | Nominal thickness | Nominal | Allowance |
mm2 | No./mm | mm | mm | mm | mm |
10.0 | 84/0.39 | 4.60 | 1.0 | 6.6 | +0.30 | 1.95 |
-0.30 |
16.0 | 126/0.39 | 5.60 | 1.0 | 7.6 | +0.30 | 1.24 |
-0.30 |
25.0 | 196/0.39 | 7.10 | 1.0 | 9.1 | +0.40 | 0.795 |
-0.40 |
35.0 | 276/0.39 | 8.30 | 1.2 | 10.7 | +0.40 | 0.565 |
-0.40 |
50.0 | 396/0.39 | 10.0 | 1.4 | 12.8 | +0.40 | 0.393 |
-0.40 |
70.0 | 360/0.49 | 11.9 | 1.6 | 15.1 | +0.50 | 0.277 |
-0.50 |
95.0 | 475/0.49 | 13.8 | 1.8 | 17.4 | +0.50 | 0.21 |
-0.50 |
120.0 | 608/0.49 | 15.8 | 2.0 | 19.8 | +0.60 | 0.164 |
-0.60 |
150.0 | 756/0.49 | 17.3 | 2.0 | 21.3 | +0.60 | 0.132 |
-0.60 |
185.0 | 925/0.49 | 19.3 | 2.2 | 23.7 | +0.80 | 0.108 |
-0.80 |
240.0 | 1221/0.49 | 22.3 | 2.4 | 27.1 | +0.80 | 0.0817 |
-0.80 |
300.0 | 1517/0.49 | 24.8 | 2.4 | 29.6 | +1.0 | 0.0654 |
-1.0 |