Use the inverter to control the synchronization of multiple motors, then how to set the parameters of the inverter
To know how to set the parameters of the inverter, you must first understand what the inverter is and what to do with it.
The inverter is a power supply device used to adjust the speed of the asynchronous motor. According to the formula of the speed n=60f/p(1-s), the inverter is essentially a voltage source with an adjustable output frequency, and the motor speed is changed by changing the power frequency. .
At the same time as the frequency changes, in order to avoid the overheating of the motor caused by magnetic flux saturation, the voltage must also be changed, that is, to keep the V/F ratio constant, so the parameter settings of the inverter are all carried out around this core.
There are many setting parameters of the inverter, and each parameter has a certain selection range. In use, it is often encountered that the inverter cannot work normally due to improper setting of individual parameters. Therefore, the relevant parameters must be set correctly. Certainly.
1. Control method
That is, speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification is generally carried out according to the control accuracy.
2. Minimum operating frequency
That is, the minimum speed at which the motor runs. When the motor runs at a low speed, its heat dissipation performance is poor. If the motor runs at a low speed for a long time, it will cause the motor to burn out.
And at low speed, the current in the cable will also increase, which will also cause the cable to heat up.
3. Maximum operating frequency
The maximum frequency of the general inverter is 60Hz, and some even reach 400Hz. The high frequency will make the motor run at a high speed. For ordinary motors, the bearings cannot run at an over-rated speed for a long time. Can the rotor of the motor withstand such centrifugal force? .
4. Carrier frequency
The higher the carrier frequency is set, the greater the higher harmonic component, which is closely related to the length of the cable, the heating of the motor, and the heating of the cable and the inverter.
5. Motor parameters
The inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, which can be directly obtained from the motor nameplate.
6. Frequency hopping
At a certain frequency, resonance may occur, especially when the entire device is relatively high; when controlling the compressor, the surge point of the compressor should be avoided.
Two or more frequency inverters synchronous control parameter setting method:
first step
Prepare two inverters, two wires, and one power supply.
second step
In the inverter wiring, the two inverters are defined as the master and the slave respectively. The port 485A of the master is connected to the port 485A of the slave, and the port 485B of the master is connected to the port 485B of the slave.
If there is a third unit, you can connect the 485A and 485B of the third unit to the 485A and 485B ports of the host computer, and so on.
third step
Inverter parameter setting. The host parameters only need to modify F05.00 to 6, in order to choose free protocol communication.
Change F05.03 to 0 as the host address.
The slave parameters need to be changed to 04 in F01.00, which is set for communication; F01.15 is changed to 2 for communication start and stop, F05.00 is changed to 06 for free protocol communication, and F05.03 is changed to 01 slave address.
If there is a third slave, the parameters are the same as the second slave, but the F05.03 address cannot be the same as the second.
the fourth step
Start the master and adjust the frequency at will, and the frequency of the slave will change with the master.