What is the cause of the inverter failure? Four-point analysis
Date: 2022/11/4Read: 35

What is the cause of the inverter failure? Four-point analysis

May 19, 2021

What is the cause of the inverter failure? Four-point analysis

The inverter will encounter faults of varying severity during use. Some may take a little time to solve, but some faults, if you do not understand the reason, to deal with it, it will take a long time and even have a counterproductive effect. Therefore, the author summarized the common faults of four frequency converters and their causes based on his many years of experience.

The author hopes that through these four points, I can help everyone.


1. Over current (short circuit)


Overcurrent faults are the most common faults in inverters. The fault is mainly caused by the following problems: First of all, the error report, as long as the speed converter starts to increase the speed, it starts to protect the fault, indicating that the overcurrent is very serious, which is mainly due to the short-circuit load, the blockage of the mechanical parts, and the soft breakdown of the inverter. Modules and too short acceleration time; secondly, once the inverter sends power, it will report a fault and cannot be "reset" to eliminate it. This is mainly due to the damage of the internal drive circuit and current detection circuit of the inverter; the last phenomenon is the worst Extremely, when the inverter is powered on or after a short delay, it will directly cause the superior air switch to trip and explode or spark inside the fuselage, and then directly break down the inverter rectifier unit and inverter power components to cause failures. . The technical protection of Minrong inverter at this point can be said to be relatively complete. Operate according to the manual of Minrong inverter. Even if this fault occurs, you can consult one-on-one Minrong experts to solve the same common faults in Minrong inverters.

2. Undervoltage


The following over-voltage faults correspond to under-voltage inverter faults, usually when the power supply voltage is too low, and there may be several reasons: power supply lacks phase, a bridge arm of the rectifier circuit, an open-circuit fault occurs, the main circuit filter electrolytic capacitor has a small capacity, or Problems with the voltage detection circuit will cause an error under the inverter voltage. In addition, if the internal slow charging resistor of the inverter is not removed by a short circuit, the inverter will report an insufficient voltage fault as long as the inverter is loaded and started.


3. Overvoltage


This failure phenomenon often occurs in inverter failures. In addition to the power supply voltage being too high, another situation occurs when the inverter is powered off. The main reason for this situation may be too short deceleration time or brake resistance and brake unit problems. Under-voltage and over-voltage are also the directions that Minrong inverters consider, not only the first point is explained, but one-to-one consultation. Some Minrong inverters have a long warranty period. Think about the user experience.


Fourth, over-temperature


Over-temperature inverter over-temperature is also a common fault, mainly due to the high operating temperature of the inverter, blockage of the radiator, damage to the cooling fan, damage to the temperature sensor, and damage to the temperature detection circuit.