USUN Model:US-2GBT double stage high pressure air driven nitrogen gas booster testing pump system...

Model
Nature of the Manufacturer
Other
Product Category
High pressure pump system
Place of Origin
City, Province
Overview
USUN Model:US-2GBT double stage high pressure air driven nitrogen gas booster testing pump system with check valve and inlet filter
Product Details


 USUN Model :US-2GBT  double Stage high pressure air driven gas booster pump system with 


Inlet gas filter and high pressure check valve and  2GBT gas booster pump included in SS frame  



2GBT

Key features

1. Realiable ,Easy to Maintain ,compact and robust

2. No heat,flame or spark risk

3. Infinitely variable cycling speed and output

4. Air driven Models do not require electrical connection ,easy to apply automatic controls

5. No limit or adverse affect to contineous stop/start applications

6.Seals system designed for long working life,No airline lubricated required

7.Built-in coupling system (Most models) and suitable for most gases boosting 

 Main technical data  


4



List items

 Function

1)  Air regulator valve

Adjustable air regulator used to adjust the air driven pressure ( 0-10 bar)

2) Air pressure gauge

Indicates the air driven pressure

3) Gas inlet Pressure gauge

Indicates the  inlet gas pressure supply

4) Gas outlet pressure gauge

Indicates the outlet boosted pressure

5) Hand drive switch

Used to adjust the system on/off

6) Inlet needle valve

Used to stop the booster when supply pressure fails to the adjust set point ,can be optional .

7) Outlet needle valve

Used to stop the booster when outlet pressure reaches the adjusted set point

8) Uploading needle valve

Used to protect the booster and other components over pressurization and release the high pressure

9) 2GBT double Stage gas booster pump

Used to increase the pressure from low pressure to high pressure

10)  InLET Gas filter

 Our standard system does not include such part ,if you need ,should inform in advance

11)  High pressure Check valev  

It does include the system and should be informed if you need it

12) High pressure safety relief valve on output

It does not include the standard system and should be informed if you need it

 

Typical technical data for air driven gas booster pump  


2GBT data-3

 

Layout drawing for 2GBT system

    Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using


of such pump ,we suggest that air driven pressure should be not more than 8 Bar
  .


Typical circuit of such Pneumatic driven gas booster pump  



2GBT circuit


Real pictures of such two stage stainless steel frame gas booster pump system 



实物图片2实物图片1