PAA11VO axial piston variable pump. Variable axial piston pump of swashplate design for hydrostatic drives in open circuit hydraulic system. Designed primarily for use in applications.
Product Details
High pressure piston pumps A11VO
PAA11VO axial piston variable pump. Variable axial piston pump of swashplate design for hydrostatic drives in open circuit hydraulic system. Designed primarily for use in applications.
Name
A11VO Series Axial piston variable pump
Series
Series 10 and 11
Sizes
40 60 75 95 130 145 190 260
Nominal Pressure
350 bar
Maximum Pressure
400 bar
Operation Mode
Open piston pump
Technical data PAA11VO
Size
A11VO
40
60
75
95
130
145
190
260
Displacement
Vg max
cm3
42
58.5
74
93.5
130
145
193
260
Vg min
cm3
0
0
0
0
0
0
0
0
Speed maximum at Vg max maximum at Vg £ Vg max
nmax
rpm
3000
2700
2550
2350
2100
2200
2100
1800
nmax1
rpm
3500
3250
3000
2780
2500
2500
2100
2300
Flow at nmax and Vg max
qv max
l/min
126
158
189
220
273
319
405
468
Power at qv max and
Δp = 350 bar
Pmax
kW
74
92
110
128
159
186
236
273
Torque at Vg max and Δp = 350 bar
Tmax
Nm
234
326
412
521
724
808
1075
1448
Rotary stiffness
Z shaft
Nm/rad
88894
102440
145836
199601
302495
302495
346190
686465
P shaft
Nm/rad
87467
107888
143104
196435
312403
312403
383292
653835
S shaft
Nm/rad
58347
86308
101921
173704
236861
236861
259773
352009
T shaft
Nm/rad
74476
102440
125603
–
–
–
301928
567115
Moment of inertia for rotary group
JTW
kgm2
0.0048
0.0082
0.0115
0.0173
0.0318
0.0341
0.055
0.0878
Angular acceleration, max.
a
rad/s2
22000
17500
15000
13000
10500
9000
6800
4800
Filling capacity
V
l
1.1
1.35
1.85
2.1
2.9
2.9
3.8
4.6
Mass (approx.)
m
kg
32
40
45
53
66
76
95
125
The pump operates under self-priming conditions, with tank pressurization, or with an optional built-in charge pump.
A comprehensive range of control options is available matching any application requirement. Power control option is externally
adjustable, even when the pump is running.
The control method is:
LR – Power control
DR – Pressure control
HD – Hydraulic control, pilot-pressure related
EP – Electric control with proportional solenoid
The through drive is suitable for adding gear pumps and axial piston pumps up to the same, i.e. 99% through drive. The output flow is proportional to the drive speed and infinitely variable between max and min.
APPLICATIOIN:
A11V(L)O series highpressure swash plate piston pump apply for open circuit system, build-incentrifugal pump which can enhance 19% max rotation speed, mainly use for travelmachine.
Driven byaxial shaft, available to connect with gear pump or axial piston pump with samespecification. The out flow is proportional to the drive speed and infinitelyvariable between maximal and zero.
1.Designed primarily for use in applications.
2.The pump operates under self-priming conditions, with tank pressurization, or with an optional built-in charge pump (impeller).
3.Power control option is externally adjustable, even when the pump is running.
4.The through drive is suitable for adding gear pumps and axial piston pumps up to the same size, i.e. 99% through drive.
Nominal pressure 5100 psi (350 bars)
Maximum pressure 5800 psi (400 bars)
1.Quick response within 2 hours
2.Accept small order (MOQ:1pcs)
3.Custom service.Unusual packaging,standard packing or as customer required
4.Excellent after-sales service
5.Strict quality control system.99% factory testing and inspection personnel in accordance with international standards for the high frequency sampling,to ensure the quality of products manufactured.
Warranty:12months.
The professional technical team will answer your questions online.