HVAC Systems Programming Heated Floor Thermostat , Underfloor Heating Room Thermostat

Model
Nature of the Manufacturer
Other
Product Category
Heated Floor Thermostat
Place of Origin
City, Province
Overview
HVAC Systems Programming Heated Floor Thermostat , Underfloor Heating Room Thermostat
Product Details

Weekly Programming Heated Floor Thermostat with LCD Screen
Weekly circulation, it is possible to set 6 periods called events each day with different temperatures, also you can select "manual mode" or "temporary control mode" according to your individual requirements. The thermostat is recommended for the control of electric heating devices or on/off valve actuator used in water-based heating systems.
 
Technical data 

Power SupplyAC200-240VAC 50/60HZ
Accuracy±0.5ºC
Probe sensorNTC
Power Consumption<0.3W
Load current3A(water heating),16A(electric heating)
Temperature Adjustable Range5°C~90°C( can adjust to 35°C~90°C)
Limit Temperature Range5°C~60°C( factory setting: 35°C)
OutputSwitch relay
Insulating conditionNormal environment
Running programSet per 1 week as a cycle
InstallationWall mounted
ApplicationWater Floor Heating System
Electric Floor Heating System
Infrared Heater System
CertificateCE,RoHS

 
Selection Table

ModelCurrentApplication
E51.7133ABuilt-in& floor sensor, floor limit sensor, weekly programming
E51.7233ABuilt-in& floor sensor, floor limit sensor, weekly programming. A potential-free output
E51.71616ABuilt-in& floor sensor, floor limit sensor, weekly programming

 
Advanced setting (qualified person preferred)
When the thermostat is turned off, You can press"" and turn on it at the same time ,then you can enter the mode of advanced setting.

SymbolSetting or
1ADJTemperature calibration

Adjust measured temperature
 

2SENSensor mode

IN: built-in sensor
OUT: floor sensor
ALL: both sensors

3.LITLimitation temperature

Adjust limitation value,
Limitation range:5℃~60℃

4DIF

Switching
differential

Adjust switching differential
5LTPAntifreeze functionTurn on/off Anti-frozen function
6PRGSet vacation mode

00: 5/2 day mode

01: 6/1 day mode
02: 7 day mode

7RLEPotential- free output and main power output in the same/different way

Change the present

linkage way

8DLYDelay time of Potential- free outputChange linkage delay time
9HITMax temperatureLimitation temperature setpoint
 AFACReset to factory settingsPress""and hold for 5s,all parameters will be reset

 
HVAC Systems Programming Heated Floor Thermostat , Underfloor Heating Room Thermostat
HVAC Systems Programming Heated Floor Thermostat , Underfloor Heating Room Thermostat