Philippines Air Purifier

Model
Nature of the Manufacturer
Other
Product Category
Home Air Purifier
Place of Origin
City, Province
Overview
It is the basic entry level model.Good for small room,such as bedroom,office,cover about 20 m2.Effective for dust,smoke,pet dander,smog
Product Details

UVC devices have been used for successful disinfection of air and surfaces in multiple industries, more specifically the healthcare industry. However, with the use of these devices it has been often noticed that there is a residual odor after disinfection, otherwise known as volatile organic compounds (VOCs). This odor has been described as a sulfuric smell similar to rotten eggs, garlic, or burning hair. A recent study by Dr. Normand Brais about residual odors from UVC disinfection has been published showing information on how UV irradiation of keratin and cysteine in dust particles from the air emit chemical byproducts of thiol and mercaptan molecules, which contain a significant amount of sulfur.


Potential Sources of Odor:

There are many possibilities as to the source of the odor following UVC disinfection that have been documented. These hypotheses include: off gassing of paint on wall surfaces, glue on UV lamps melting or overheating, or contact with air and surface dust. Nevertheless, off gassing of paint was negated once using UV devices in paint less rooms as well as the glue on UV lamps after it was revealed that removing the glue did not have any effect on the presence or absence of smell. The hypothesis of UV disinfection on air and surface dust was finalized after the study performed multiple tests in the same enclosure and after each test the odor seemed to decrease.


Composition of Airborne Dust:

Dust in human environments consists of around 80% dead human skin and hair cells, and the rest a small percent from environmental fibers, minerals, and cells. The main components of dead human skin and hair cells are keratin and its amino acid, cysteine. Keratin is a fibrous protein found in skin cells on the outer layer of the human skin, hair, and nails. Cysteine is a sulfur containing amino acid typically found in dust particles due to being bound by keratin in hair. Keratin consists of a long chain of large amounts of cysteine that contains sulfur. Atomically, sulfur provides a site on the substances for the formation of a strong chemical bond with other molecules and thus allows for strength and stability to hold together keratin fibers.


UVC, Keratin, and Cysteine:

UVC light has high energy that can break chemical bonds and break larger molecules into smaller molecules. “The energy of germicidal UV photons at 254 nm wavelength is 470 kJ/mol" (Brais) and is higher than the average chemical bond energy (bond enthalpies) of all of the chemical compositions in keratin and cysteine. A higher energy potential of UV energy compared to the energy in chemical bonds allows for the breaking of these bonds (see table below). The broken chemical bonds between certain atoms may contain the remaining sulfur and will create a sulfur compound called thiol or mercaptan.


Sulfur Compound Concentration Smell Threshold:

Thiols and mercaptans have an extremely low smell threshold and humans can easily detect thiols at extremely low concentrations. The breaking of multiple sulfide bonds, as listed in the table below, can give of a variety of different smells that the human nose can detect. Consequently, the smell after disinfection using a UVC device is the breaking of these bonds during sterilization.Concentrations of thiol after UV disinfection end up being around 200 parts per billion (ppb) in volumetric concentration, and according to ASHE the “acceptable level for 8 hr exposure is 0.5 parts per million (ppm) or 500 ppb" (Brais). Therefore, levels of thiol concentration due to UV disinfection are deemed as safe to human exposure.


Conclusion:

The amount of human skin cells in dust concentrations due to human presence in areas that UVC devices disinfect is extremely high. With high levels of keratin and cysteine in the dust particles, the breaking of chemical bonds in both molecules causes the formation of sulfur containing thiols. With the low threshold of human detection to smell, thiols are the reason why UV devices cause a potentially unpleasant odor in rooms after disinfection.