MS series aluminum housing 3kw 3 phase motor is made of superior materials and conform to the IEC standard. MS motors have good performance, low noise, safety, reliable operation and nice appearance. It can be maintained very conveniently. This motor has advantages of little vibration, light weight and simple construction. These motor can be used for general drive such as water pumps, water treatment, road machinery, petroleum, chemical, metallurgy, cement and paper industries.
Product Detail
Motor Type: 3 phase 3kw motor
Output Power: 0.06 kW - 18.5 kW
Frame Size: IEC Frame 56 - 160
Number of Poles: 2 / 4 / 6 / 8
Voltage: 220/380V, 380/660V, 230/400V, 400/690V
Frequency: 50 & 60 Hz
Protection Level: IP54 / IP55
Energy Efficiency Rating: IE1 / IE2 / IE3
Insulation Class: B/F
Cooling Method: IC411
Working System: S1
Product Parameter (Specification)
Type | Power (KW) | Rated Current (A) | Speed (r/min) | Eff (%) | Power Factor CosØ | Rated Torque Tn(N*m) | Tst/Tn | Tmax/Tn | Ist/In | |||||
220V | 380V | 660V | 230V | 400V | 690V | |||||||||
3000rpm.2 poles | ||||||||||||||
MS2-100L-2 | 3 | 10.7 | 6.18 | 3.57 | 10.19 | 5.88 | 3.4 | 2880 | 84.6 | 0.87 | 9.95 | 2.3 | 2.3 | 7.8 |
1500rpm.4 poles | ||||||||||||||
MS2-100L2-4 | 3 | 11.37 | 6.56 | 3.79 | 10.83 | 6.25 | 3.61 | 1440 | 85.5 | 0.81 | 19.9 | 2.3 | 2.3 | 7.5 |
1000rpm. 6 poles | ||||||||||||||
MS2-132S-6 | 3 | 13.13 | 7.58 | 4.38 | 12.51 | 7.22 | 4.17 | 960 | 83.3 | 0.72 | 29.84 | 2 | 2.1 | 6.4 |
Production Features





Know More Us


Why Us

Service and Packing

Motor cooling system
The air-cooled motor has a simple structure and low cost; its disadvantage is that the cooling effect of air is poor, and the friction loss caused by the high-speed motor is relatively large. There are many structural types of ventilation systems using air cooling
Suction type and press-in type
According to whether the cooling air first passes through the heating part of the motor, and then through the fan, or vice versa, air-cooled systems can be divided into two types: suction type and press-in type. Since the inhaled cold air first contacts the heating part of the motor, and a fan with a larger diameter can be used, the press-in cooling air first passes through the fan, is heated by the loss of the fan, and then contacts the heating part of the motor ( In high-speed motors, the air temperature rise caused by fan loss can reach about 5°C), so the suction cooling capacity is relatively high.
In DC motors, the fans are mostly installed at the non-commutator end. For example, a press-in cooling system can prevent the carbon powder worn by the brushes from entering the motor, but at this time, most of the air volume blows through the space between the stator poles and blows the rotor. The less air volume makes it difficult for the rotor with more loss to dissipate heat. At this time, appropriate measures must be taken, such as fully relying on the air duct piece of the armature core and the blast effect of the winding end to dissipate heat.
External cooling and internal cooling
Air-cooled systems generally use external cooling or so-called surface cooling, but in order to improve the cooling capacity, there are also internal cooling methods. For example, the field winding of a hydro-generator can use air internal cooling. In foreign countries, internal air cooling has also been used on the rotor windings of turbine generators with small capacity. However, the internal cooling system has a complex structure and requires very clean cooling gas, so it is rarely used in motors that use air as the cooling medium.
,