E-mail
arisa@jindian2008.com
- Phone
-
Address
No. 18, Minyuan Road, Tongshan New District, Xuzhou City, Jiangsu Province
Membership
Help
Xuzhou Sanhe Automatic Control Equipment Co., Ltd.Free·1YRS
arisa@jindian2008.com
No. 18, Minyuan Road, Tongshan New District, Xuzhou City, Jiangsu Province
Our company specializes in R&D, production and sales of microcomputer temperature controllers and humidity controllers. The chip used in the temperature controller has stable performance, complete functions, multiple protections, advanced and reasonable structural design and process processing, and the technical level is internationally advanced and domestically leading . This product has a wide range of applications in the field and industry of freezing and refrigeration and refrigeration maintenance. Our company can also design and customize products according to customer requirements.
Switch the mode between heating and refrigerating
Controlling the temperature by adjusting both the temperature setting value and difference value
Delay protection when refrigerating and heating starts
Limit the temperature setting range
Calibrate the temperature
Alarm when sensor error
Product size:77*34.5*62mm
Front panel size:77*34.5mm
Installation size:71*29mm
Sensor:2 meters(probe included)
Power supply:220VAC±10%/-15%,50/60Hz
Power consumption:≤3W
Temperature measuring range:-40℃~99℃
Temperature controlling range:-40℃~99℃
Resolution: 1℃
Accuracy:±1℃,±0.5digit
Relay output capacity:10A(0.5HP)/220VAC
Delay time when sensor error:1 min
Sensor type:NTC sensor
Safety level of the front panel:IP54
Operating temperature:0℃~60℃
Storage temperature:-30℃~75℃
Relative humidity:20%~85%(No condensate)
Relay connects or disconnects when:
When working mode is set as “Refrigerating",the relay connects if the measuring
temperature is above or equal to the setting temp.value plus the difference value; and relay disconnects when measuring temp.value is below or equal to the setting temp. value.
When working mode is set as Heating",the relay will connect if the measuring temp. value is below or equal to the setting temp.value; the relay will disconnect when the measuring temperature is above or equal to the setting temp. value plus the difference value.
LED displays"HH when temperature is between +99℃~+120℃;LED displays "EE" and system cose the output when sensor error. The controller can restart up or close only when the control output delay time is running out.
★Danger:
Please strictly distinguish the connections of relay, sensor and power. Make sure the relayis not overload.
all the wire connection must be operated under the power off status.
★Warning:
Prohibit to use the controller under the circumstances such as :over moisture, over high temperature, strong electromagnetic interference, strong corrosion
★Notice:
Make sure the voltage confirm to the marking on the machine and the power supply steady. It is advised to keep proper distance between sensor leads and power supply wire to avoid possible interference.