| Model | Tracer6210AN | Tracer5415AN | Tracer6415AN | Tracer8415AN | Tracer10415AN | Tracer5420AN | Tracer6420AN | Tracer8420AN | Tracer10420AN |
| Nominal system voltage | 12/24VDC/Auto | 12/24/36/48VDC/Auto |
| Battery type | Lead-acid (Sealed/Gel/Flooded)/Lithium (LiFePO4/Li(NiCoMn)O2)/User |
| Battery input voltage range | 8V~32V | 8V~68V | 8V~68V | 8V~68V | 8V~68V | 8V~68V | 8V~68V | 8V~68V | 8V~68V |
| Rated charge current | 60A | 50A | 60A | 80A | 100A | 50A | 60A | 80A | 100A |
| Rated charge power | 750W/12V 1500W/24V | 625W/12V 1250W/24V 1875W/36V 2500W/48V | 750W/12V 1500W/24V 2250W/36V 3000W/48V | 1000W/12V 2000W/24V 3000W/36V 4000W/48V | 1250W/12V 2500W/24V 3750W/36V 5000W/48V | 625W/12V 1250W/24V 1875W/36V 2500W/48V | 750W/12V 1500W/24V 2250W/36V 3000W/48V | 1000W/12V 2000W/24V 3000W/36V 4000W/48V | 1250W/12V 2500W/24V 3750W/36V 5000W/48V |
| Max. conversion efficiency | 98.00% | 98.30% | 98.60% | 98.50% | 98.60% | 98.30% | 98.10% | 98.50% | 98.50% |
| Tracking efficiency | ≥99.5% |
| Max. PV open circuit voltage | 100V(At minimum operating environment temperature) 92V(At 25℃ environment temperature ) | 150V(At minimum operating environment temperature) 138V(At minimum operating environment temperature) | 200V(At minimum operating environment temperature) 180V(At minimum operating environment temperature) |
| MPP voltage range | (Battery Voltage+2V) ~72V | (Battery Voltage +2V)~108V | (Battery Voltage+2V)~144V |
| Equalization voltage | Sealed:14.6V,Flooded:14.8V,User-defined:9-17V |
| Boost voltage | Gel:14.2V,Sealed:14.4V,Flooded:14.6V,User-defined:9-17V |
| Float voltage | Gel/Sealed/Flooded:13.8V,User-defined:9-17V |
| Low voltage reconnect voltage | Gel/Sealed/Flooded:12.6V,User-defined:9-17V |
| Low voltage disconnect voltage | Gel/Sealed/Flooded:11.1V,User-defined:9-17V |
| Self-consumption | 98mA/12V;60mA/24V;50mA/36V;46mA/48V |
| Temperature compensation( for lead-acid battery) | -3mV/℃/2V(Default) |
| Relative humidity | 5% to 95% (N.C.) |
| Enclosure | IP20 |
| Communication interface | RS485(5VDC/200mA, Two RJ45 ports in parallel) |
| Grounding | Common negative |
| Operating temperature range | `-25℃~+60℃(derating above 45℃) |
| Dimensions(LxWxH)(mm) | 340×232×105.2 | 261×216×119 | 340×236×119 | 394×240×134 | 394×242×143 | 261×216×119 | 340×236×119 | 394×240×134 | 394×242×143 |
| Net weight | 3.5kg | 3.5kg | 4.5kg | 6.1kg | 7.4kg | 3.5kg | 4.5kg | 6.1kg | 7.4kg |
1. The controller can't automatically identify system voltage if lithium batteries were connected.
|
| 2. The voltage point is for the 12V system, please *2 in 24V system, *3 in 36V system, *4 in 48V system. |