Energy storage system for solar power (ESS) refers to the device of converting electrical energy from power systems into a form that can be stored for converting back to electrical energy when needed.Villa,Hotel,Office building,Hospital,Museum,Church,Farm
Residential Hybrid Inverter (Three Phase) LEI-10K / 12K / 15K / 20K-TL
Product Features:
Compatible with various batteries,perfect protection function & strong environmental adaptability
Wide DC input voltage range design
Multi-channel PV MPPT access to improve power generation utilization
Off-grid output connection unbalanced load, support three phase independent output
Ingress protection IP65, wall mounted design
Battery reverse polarity protection
Compatible anti-backflow function
Seamless switching between off-grid and on-grid
Max. efficiency up to 98.2%
Multiple working mode:Self-use mode, Time-of-use mode, Timing mode, Passive mode
Remote monitoring of PC and phones

WORKING MODES
Self-consumption Mode
Throughout the day, the power generated by PV system will supply household loads first , and then saving surplus energy to battery that can be used at any time, the excess electricity could be exported to grid.
Time-of-use Mode
Battery charging and discharging time can be flexibly set based on your local peak and off-peak electricity period to minimum the electricity bills.
Backup Mode
Back-up mode is able to maintain the battery in a charged state. When power outage happens, the battery discharges to power the backup loads.
Technical Specifications
Model | LEI-10K-TL | LEI-12K-TL | LEI-15K-TL | LEI-20K-TL |
PV Input |
PV Input Power [W] | 15000 | 18000 | 22500 | 30000 |
Start-up Voltage [V] | 200 |
Max. PV Input Voltage [V] | 1000 |
MPPT Voltage Range [V] | 180~960 |
MPPT Working Voltage For Full Load [V] | 220~850 | 264~850 | 350~850 | 450~850 |
MPPT Number/Max. Number of Strings Per Channel | 2/2 |
Max. MPPT Input Current [A] | 50 (25/25) |
Battery |
Battery Type | Lithium,Lead-acid |
Number Of Battery Input | 2 |
Battery Voltage Range [V] | 180~800 |
Battery Voltage Range For Full Load [V] | 200~800 | 240~800 | 300~800 | 400~800 |
Max. Charge&Discharge Current [A] | 50 (25/25) |
Communication | CAN/RS485 |
Charging Strategy For Battery | According to BMS instructions/3 Stages (Lead-acid) |
AC Output (Grid-side) |
Rated Output Power [W] | 10000 | 12000 | 15000 | 20000 |
Max. Output Power [VA] | 11000 | 13200 | 16500 | 22000 |
Rated Output Voltage [V] | 3/N/PE,220/380,230/400 |
Grid Voltage Range [V] | 184~276 |
Max. Output Current [A] | 16 | 19 | 24 | 32 |
AC Output Frequency [Hz] | 50/60 (45~54.9/54.9~65) |
Power Factor | 1 (0.8 leading~0.8 lagging) |
THDi (Rated Power) | <3% |
Backup AC Output (EPS) |
Rated Backup Output Power [VA] | 10000 | 12000 | 15000 | 20000 |
Max. Backup Output Power [VA] | 11000 60s,15000 1s | 13200 60s,18000 1s | 16500 60s,22500 1s | 22000 60s,30000 1s |
Max. Output Current [A] | 16 | 19 | 24 | 32 |
Backup Output Voltage [V] | 3/N/PE,220/380,230/400 |
AC Frequency [Hz] | 50/60 (±0.2%) |
THDu (@linear load) | <3% |
Switch Time | <10ms |
Efficiency |
Max. Efficiency | 98.2% |
General Data |
Temperature Range [℃] | -25~+60 |
Relative Humidity | 0~95% |
Altitude [m] | 0~4000 ( >2000 derating) |
Cooling Method | Smart fan cooling |
Noise [dB] | <40 |
Display | LCD |
Communication | RS485 (Standard); Wi-Fi/GPRS/Ethernet (Option) |
BMS Communication | RS485/CAN |
Weight [kg] | 37 |
Dimension (W*D*H) [mm] | 591*271*585 |
Installation Style | Wall-mounted |
Ingress Protection | IP65 |
Standby Self Consumption [W] | <15 |
Grid Standard | VDE4105/EN50549 |
Safety Standard | CE/IEC62109 |
Protection |
DC Lightning Protection | Yes |
AC Lightning Protection | Yes |
PV Reverse Polarity Protection | Yes |
Battery Reverse Protection | Yes |
Insulation Resistor Detection | Yes |
Leakage Current Detection | Yes |
Anti-island Protection | Yes |
Grounding Fault | Yes |
Input Overvoltage & Unervoltage | Yes |
Output Overvoltage & Unervoltage | Yes |
Input Over Current | Yes |
Output Over Current | Yes |
Overheat Protection | Yes |