LEI-30K / 50K / 60K / 100K / 125K / 150K-TTProduct FeaturesCan be used in high-altitude, alpine areasMulti-channel PV MPPT access to improve power generation utilizationPower frequency topology, industrial designWide DC input voltage range design, compatible with various batteriesHigh-performance DSP, optimized control circuit design, better performanceIntelligent management control strategy, multiple working modes, online or remote switchingCold start with load, three-phase 99% unbalanced load, strong load adapta......
Commercial Hybrid Inverter (Built-in Transformer) LEI-30K / 50K / 60K / 100K / 125K / 150K-TT
Working Mode:
- Self-use mode: Priority use of the photovoltaic power generation and guarantee the work of important loads. Excess photovoltaic power will be stored in the battery or grid in turn; If the photovoltaic and battery power is insufficient, the power can be taken from the grid to ensure the load work.
- Off-grid mode: When there is a grid failure/ power cut, the device can automatically switch to off-grid mode via STS. The system continues to supply power to the local load from photovoltaic and batteries.
- Remote mode: The machine can be controlled through the background monitoring software for various working modes.
Product application scenario & schematic diagram

Technical Specifications
Model | LEI-30K-TT | LEI-50K-TT | LEI-60K-TT | LEI-100K-TT | LEI-125K-TT | LEI-150K-TT |
DC Input (PV) | | | | | | |
Max. Input Voltage [V] | 850 |
MPPT Voltage Range [V] | 600~850 |
Number of MPPTs | 3 |
Max. Input Power Per MPPT [kW] | 10 | 20 | 30 |
DC Input (Battery) | | | | | | |
Battery Type | Lithium,Lead-Carbon,Lead Acid etc |
Operating Voltage Range [V] | 320~600 | 400~600 |
AC Output (Grid-side) | | | | | | |
Rated Output Power [kW] | 30 | 50 | 60 | 100 | 125 | 150 |
Max. Output Apparent [kVA] | 33 | 55 | 66 | 110 | 137 | 165 |
Rated Grid Voltage [V] | 3/N/PE,230/400 |
Rated Grid Frequency [Hz] | 50/60 |
AC Output (Loads) | | | | | | |
Rated Output Power [kW] | 30 | 50 | 60 | 100 | 125 | 150 |
Max. Output Apparent [kVA] | 33 | 55 | 66 | 110 | 137 | 165 |
Overload Capacity | 110% for Ten Minutes,120% for One Minutes |
Rated Grid Voltage [V] | 3/N/PE,230/400 |
Rated Grid Frequency [Hz] | 50/60 |
THDi | <3% (Rated power) |
Unbalanced Load Capacity | 99% |
Protection | | | | | | |
AC Short Circuit Protection | Yes |
DC Reverse Polarity Protection | Yes |
Surge Protection | Yes (PV-side & Grid-side) |
Efficiency | | | | | | |
Max. Efficiency | 92% | 93.0% | 94.0% |
General Data | | | | | | |
Dimensions (W*D*H)[mm] | 950*700*1953 | 1200*800*2050 |
Net Weight [kg] | 650 | 650 | 800 | 900 | 1050 | 1250 |
Isolation Transformer | Yes |
Temperature Range [℃] | -30~+55 |
Shutdown Self power Consumption [W] | <50 |
Cooling Method | Forced air cooling |
Installation Style | Cabinet Installation |
Ingress Protection | IP20 |
Relative Humidity | 0~95%,non-condensing |
Max. Altitude [m] | 5000 (>3000 Derating) |
Display Mode | Touch screen |
Dispatching Communication Mode | Ethernet,RS48 |
BMS Communication Mode | RS485,CAN |
Communication Protocol | Modbus-RTU/TCP |
Project